All Products

20PV27 - Fusibile 2000VDC gPV 27x85mm 100A

Reference 241.208.32.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 100
Applicable standards IEC
Power loss (W) 21.1
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV27
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 27x85
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 inline 45A 6/8 AWG

Reference 212.218.36.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 45
Applicable standards IEC
Power loss (W) 11.9
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 inline 65A 6/8 AWG

Reference 213.415.06.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 65
Applicable standards IEC
Power loss (W) 15.4
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type In-line for copper cable
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 40A

Reference 226.616.51.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 40
Applicable standards IEC
Power loss (W) 11.3
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 415
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

B050 - Fuse 1000VDC aBat 400A - 118,85mm - Tin Plated

Reference 209.159.68.0.0 - Manufacturer FAULTRAP
Class aBat, aR
Rated current In (A) 400
Applicable standards IEC, UL
Power loss (W) 55
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B050
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 50x141
Melting I²t value (A²s) 44300
Minimum breaking current (A) 4000
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 118
Total clearing I²t @Un DC (A²s) 115500