All Products

Fuse NH2 400V gG 630A

Reference 3103630.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 630
Rated Voltage Un AC (V) 400
Dimension NH3
Applicable standards IEC
Power loss (W) 29
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 970
Product available on request Ask for more information

Fuse NH2 400V gG 200A

Reference 3103C200.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 17
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 224A

Reference 3103C224.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 18,7
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 250A

Reference 3103C250.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 19,2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 300A

Reference 3103C300.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 300
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 21
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 315A

Reference 3103C315.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 23,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 355A

Reference 3103C355.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 25
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 400A

Reference 3103C400.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 400
Rated Voltage Un AC (V) 400
Dimension NH3C
Applicable standards IEC
Power loss (W) 25,6
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 655
Product available on request Ask for more information

Fuse NH2 400V gG 1000A

Reference 3104101.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 1000
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 72
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information

Fuse NH2 400V gG 1250A

Reference 3104126.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 1250
Rated Voltage Un AC (V) 400
Dimension NH4a
Power loss (W) 100,5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 1950
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist