All Products

Fuse NH2 gR 500V with striker 40A

Reference 2001004.40.0 - Manufacturer SIBA
Class gR
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 9,2
Melting I²t value (A²s) 90
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 740
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gR 500V with striker 50A

Reference 2001004.50.0 - Manufacturer SIBA
Class gR
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 11,5
Melting I²t value (A²s) 190
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1560
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gR 500V with striker 63A

Reference 2001004.63.0 - Manufacturer SIBA
Class gR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 14.5
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gR 500V with striker 80A

Reference 2001004.80.0 - Manufacturer SIBA
Class gR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 18
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 gG 500V with striker 100A

Reference 2001013.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 224A

Reference 2001013.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 16,4
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 483400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €31.93/pc
Quantity

Fuse NH2 gG 500V with striker 35A

Reference 2001013.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 50A

Reference 2001013.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 63A

Reference 2001013.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH3 aR 500V with striker 160A

Reference 2001104.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 48
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 224A

Reference 2001104.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 61
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 250A

Reference 2001104.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 65
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 51000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 355A

Reference 2001104.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 83
Melting I²t value (A²s) 20000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 125000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 450A

Reference 2001104.450.0 - Manufacturer SIBA
Class aR
Rated current In (A) 450
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 90
Melting I²t value (A²s) 38000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 190000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 550A

Reference 2001104.550.0 - Manufacturer SIBA
Class aR
Rated current In (A) 550
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 110
Melting I²t value (A²s) 57000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 300000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 700A

Reference 2001104.700.0 - Manufacturer SIBA
Class aR
Rated current In (A) 700
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 135
Melting I²t value (A²s) 106000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 560000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 930
Product available on request Ask for more information

Fuse NH3 gG 500V with striker 355A

Reference 2001113.355.0 - Manufacturer SIBA
Class aM
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 30
Melting I²t value (A²s) 616000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1483000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Price List €43.58/pc
Quantity

Fuse NH4 gG 500V with striker 400A

Reference 2001213.400.0 - Manufacturer SIBA
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 28
Melting I²t value (A²s) 859000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2008000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 500A

Reference 2001213.500.0 - Manufacturer SIBA
Class aM
Rated current In (A) 500
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 38
Melting I²t value (A²s) 1130000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 2800000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 630A

Reference 2001213.630.0 - Manufacturer SIBA
Class aM
Rated current In (A) 630
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 49
Melting I²t value (A²s) 1950000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 4840000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 710A

Reference 2001213.710.0 - Manufacturer SIBA
Class aM
Rated current In (A) 710
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 800A

Reference 2001213.800.0 - Manufacturer SIBA
Class aM
Rated current In (A) 800
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 66
Melting I²t value (A²s) 3700000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 8900000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 850A

Reference 2001213.850.0 - Manufacturer SIBA
Class aM
Rated current In (A) 850
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Rated breaking capacity I1 AC (kA) 120000
Price List €159.57/pc
Quantity

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 160A

Reference 2001927.160.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 160
Dimension SQB1
Applicable standards IEC
Power loss (W) 36
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 25000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist