All Products

Fuse 12kV 63,5x310 M8-G1/8” oiltight 50A

Reference 3031016.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 56
Fuse Dimension (mm) 63,5x310
Melting I²t value (A²s) 5700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2780
Product available on request Ask for more information

Fuse 12kV 63,5x310 M8-G1/8” oiltight 6,3A

Reference 3031016.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 16
Fuse Dimension (mm) 63,5x310
Melting I²t value (A²s) 45
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 360
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2780
Product available on request Ask for more information

Fuse 12kV 63,5x310 M8-G1/8” oiltight 63A

Reference 3031016.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 63
Fuse Dimension (mm) 63,5x310
Melting I²t value (A²s) 10700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 66000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2780
Product available on request Ask for more information

Fuse 12kV 63,5x310 M8-G1/8” oiltight 80A

Reference 3031016.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 120
Fuse Dimension (mm) 63,5x310
Melting I²t value (A²s) 17500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 175000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2780
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 12A

Reference 3031091.12.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 12
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 340
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 3800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 20A

Reference 3031091.20.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 20
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 20
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1730
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 17300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Product available on request Ask for more information

Fuse 17,5kV63,5x360general purpose M8-G1/8” +striker12A 50N

Reference 3031096.12.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 12
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 340
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 3800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 17,5kV63,5x360general purpose M8-G1/8” +striker8A 50N

Reference 3031096.8.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 8
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 8
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 172
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8 oiltight with striker 63A 50N

Reference 3031215.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 144
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 8700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 87000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €150.12/pc
Quantity

Fuse 24kV 63,5x360 M8 oiltight with striker 80A 50N

Reference 3031215.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 176
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2519
Price List €153.43/pc
Quantity

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 10A 50N

Reference 3031216.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 54
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 20A 50N

Reference 3031216.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 28
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 550
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 25A 50N

Reference 3031216.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 58
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 920
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 9200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 31,5A 50N

Reference 3031216.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 76
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 40A 50N

Reference 3031216.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 94
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 2200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 22000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 50A 50N

Reference 3031216.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 108
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 47000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 6,3A 50N

Reference 3031216.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 30
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 30
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 160
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2590
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 63A 50N

Reference 3031216.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 114
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 8700
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 87000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 M8-G1/8” oiltight with striker 80A 50N

Reference 3031216.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 176
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2000
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose without striker 6,3A

Reference 3031291.6,3.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2410
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 10A 50N

Reference 3031295.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 630000
Weight (gr) 2410
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 20A 50N

Reference 3031295.20.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1730
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 17300
Rated breaking capacity I1 AC (kA) 630000
Weight (gr) 2700
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 10A 50N

Reference 3031296.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 21
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information

Fuse 24kV 63,5x360 general purpose with striker 6,3A 50N

Reference 3031296.6,3.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist