B100 - Fuse 1000VDC aBat 900A - 152,7mm - Silver Plated

Reference 456.383.65.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 900
Applicable standards IEC, UL
Power loss (W) 170
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x203,2
Melting I²t value (A²s) 267000
Minimum breaking current (A) 9000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 813000
Product available on request Ask for more information

NR2B - Fuse DIN00 80mm aR 700VDC/690VAC with ind. lug 200A

Reference 456.865.11.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC, UL
Power loss (W) 48.5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2B
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 5370
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 19600
Rated breaking capacity I1 AC (kA) 200000
Price List €60.82/pc
Quantity

B100 - Fuse 1000VDC aBat 750A - 152,7mm - Silver Plated

Reference 456.954.32.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 750
Applicable standards IEC, UL
Power loss (W) 140
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x130,5
Melting I²t value (A²s) 166000
Minimum breaking current (A) 7500
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 500000
Product available on request Ask for more information

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC no ind 200A

Reference 456.980.23.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 48,5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 5370
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 19600
Rated breaking capacity I1 AC (kA) 200000
Price List €49.30/pc
Quantity

NRAB - Fuse 690V AC aR NH00 with indicator 25A

Reference 458.370.74.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 4,6
Series name NRAB
Melting I²t value (A²s) 55
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 770
Total clearing I²t @Un AC (A²s) 265
Rated breaking capacity I1 AC (kA) 200000
Product available on request Ask for more information

B100 - Fuse 1000VDC aBat 1000A - 132,7mm - Tin Plated

Reference 459.971.59.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 1000
Applicable standards IEC, UL
Power loss (W) 175
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B100
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 63,5x167
Melting I²t value (A²s) 373500
Minimum breaking current (A) 10000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 1095000
Product available on request Ask for more information

B025 - Fuse 1000VDC aBat 300A - 100,3mm - Silver Plated

Reference 460.577.02.0.0 - Manufacturer FAULTRAP
Class aBat, aR
Rated current In (A) 300
Applicable standards IEC, UL
Power loss (W) 47
Rated Voltage Un DC (V) 1000
Time costant L/R (ms) 2
Series name B025
Rated breaking capacity I1 DC (kA) 100
Fuse Dimension (mm) 38x129
Melting I²t value (A²s) 23300
Minimum breaking current (A) 2400
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 100
Total clearing I²t @Un AC (A²s) 51000
Product available on request Ask for more information

20PV22 - Fuse 2000VDC gPV 22x85 20A

Reference 463.061.50.0.0 - Manufacturer FAULTRAP
Class gPV
Rated current In (A) 20
Applicable standards IEC
Power loss (W) 6.4
Rated Voltage Un DC (V) 2000
Time costant L/R (ms) 1-3
Series name 20PV22
Rated breaking capacity I1 DC (kA) 50
Fuse Dimension (mm) 22x85
Melting I²t value (A²s) 67
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

EV65.1500 - Fuse 1500VDC 22x65 cylindrical 70A

Reference 463.473.97.0.0 - Manufacturer FAULTRAP
Class EV full
Rated current In (A) 70
Applicable standards UL
Power loss (W) 13
Rated Voltage Un DC (V) 1500
Time costant L/R (ms) 2,5
Series name EV65.1500
Rated breaking capacity I1 DC (kA) 25000
Fuse Dimension (mm) 22x65
Melting I²t value (A²s) 2010
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 10500
Product available on request Ask for more information

S276 - Fuse 27x60mm 500VAC gS PCB 200A

Reference 463.850.17.0.0 - Manufacturer FAULTRAP
Class gRL, gS
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 9
Series name S276
Rated breaking capacity I1 DC (kA) 100000
Fuse Dimension (mm) 27x60
Melting I²t value (A²s) 5200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 550
Total clearing I²t @Un AC (A²s) 27600
Product available on request Ask for more information