All Products

Fuse NH2 gG 690V insulated cover double indicator 160A

Reference 2045613.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.43/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 200A

Reference 2045613.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16,5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.44/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 224A

Reference 2045613.224.0 - Manufacturer SIBA
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 18,1
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 470000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €44.58/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 250A

Reference 2045613.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 20,2
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 690000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €45.06/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 315A

Reference 2045613.315.0 - Manufacturer SIBA
Class gG
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 24,1
Melting I²t value (A²s) 513000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1200000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 640
Price List €49.13/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 355A

Reference 2045613.355.0 - Manufacturer SIBA
Class gG
Rated current In (A) 355
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 28,6
Melting I²t value (A²s) 616000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1600000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 640
Price List €53.97/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 160A

Reference 2044113.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 309
Price List €12.55/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 200A

Reference 2044113.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 420
Price List €14.80/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 224A

Reference 2044113.224.0 - Manufacturer SIBA
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 16,2
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 483400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 420
Price List €16.53/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 250A

Reference 2044113.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 17,9
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 616000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 333
Price List €16.54/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 35A

Reference 2044113.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7610
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 310
Price List €17.23/pc
Quantity

Fuse NH1 gG 500V insulated cover double indicator 50A

Reference 2044113.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 300
Price List €10.44/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.