Fuse NH1 gG 690V insulated cover double indicator 16A

Reference 2045513.16.0 - Manufacturer SIBA
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,2
Melting I²t value (A²s) 420
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €30.35/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 160A

Reference 2045513.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.39/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 20A

Reference 2045513.20.0 - Manufacturer SIBA
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 2,7
Melting I²t value (A²s) 760
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €30.35/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 200A

Reference 2045513.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 16,5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €32.45/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 224A

Reference 2045513.224.0 - Manufacturer SIBA
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 18,2
Melting I²t value (A²s) 194800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 615000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €32.45/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 25A

Reference 2045513.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 3,1
Melting I²t value (A²s) 1440
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 250A

Reference 2045513.250.0 - Manufacturer SIBA
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 20,1
Melting I²t value (A²s) 240800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 690000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €35.86/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 32A

Reference 2045513.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 3,8
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 6000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 35A

Reference 2045513.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,2
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 8500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 40A

Reference 2045513.40.0 - Manufacturer SIBA
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,7
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 12500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 50A

Reference 2045513.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 5,5
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 15000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 63A

Reference 2045513.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 6.3
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 21600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc