All Products

Fuse 12kV 63,5x254 F01 oiltight 90A

Reference 3014436.90.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 90
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Fuse Dimension (mm) 63,5x254
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 157000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 1860
Price List €282.95/pc
Quantity

Fuse 12kV 76x359 back-up FA2 80A

Reference 3014736.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Fuse Dimension (mm) 76x359
Melting I²t value (A²s) 27200
Fuse Connection/Terminal type BS
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 81000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2500
Price List €541.30/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 16A

Reference 3015636.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 190
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €266.61/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 20A

Reference 3015636.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 290
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 2900
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €267.49/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 31,5A

Reference 3015636.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 10000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €296.27/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 50A

Reference 3015636.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 2800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 36000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €300.94/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 6,3A

Reference 3015636.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 14
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 140
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €254.72/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 63A

Reference 3015636.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 6500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 65500
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €305.80/pc
Quantity

Fuse 24kV 63,5x359 F02 oiltight 80A

Reference 3015636.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 63,5x359
Melting I²t value (A²s) 9900
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 100000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2450
Price List €330.79/pc
Quantity

Fuse 17,5kV 53x367 back-up no striker 0,5A

Reference 3017611.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 8,1
Resistance (ohm) 29,48
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2010
Price List €51.41/pc
Quantity

Fuse 17,5kV 53x367 back-up no striker 1A

Reference 3017611.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 6,2
Resistance (ohm) 4,64
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 1,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2010
Price List €70.63/pc
Quantity

Fuse 17,5kV 53x367 back-up without striker 2A

Reference 3017611.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 2,06
Fuse Dimension (mm) 53x367
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2010
Price List €93.43/pc
Quantity
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist