All Products

Fuse 12kV 85x537 back-up striker no temp.lim315ARC215

Reference 3021114.315.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 315
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 142
Resistance (ohm) 0,002
Fuse Dimension (mm) 85x537
Melting I²t value (A²s) 585000
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 2400000
Rated breaking capacity I1 AC (kA) 80000
Weight (gr) 6920
Price List €935.13/pc
Quantity

Fuse 17,5kV 67x292 back-up without striker 2A

Reference 3022111.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Fuse Dimension (mm) 67x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 63000
Rated breaking capacity I1 AC (kA) 17500
Weight (gr) 2540
Price List €117.46/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 20A 80N

Reference 3022113.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 36
Resistance (ohm) 0,062
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 4400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €281.19/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 25A 80N

Reference 3022113.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 43
Resistance (ohm) 0,048
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €287.52/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 31,5A 80N

Reference 3022113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 56
Resistance (ohm) 0,039
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €294.09/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 40A 80N

Reference 3022113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 71
Resistance (ohm) 0,029
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 17500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €297.22/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 50A 80N

Reference 3022113.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 81
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €304.62/pc
Quantity

Fuse 17,5kV 67x292 back-up with striker 63ARC56 80N

Reference 3022113.63.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 63
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 71
Resistance (ohm) 0,016
Fuse Dimension (mm) 67x292
Melting I²t value (A²s) 8700
Minimum breaking current (A) 210
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 61400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2550
Price List €312.54/pc
Quantity

Fuse 10/17,5kV 31,5A

Reference 3022114.31,5.0 - Manufacturer SIBA
Price List €167.60/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 100ARC90 80N

Reference 3022213.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 109
Resistance (ohm) 0,0087
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 199000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €316.43/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 125ARC95 80N

Reference 3022213.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 114
Resistance (ohm) 0,0079
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 35000
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 247000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €333.18/pc
Quantity

Fuse 17,5kV 85x292 back-up with striker 160ARC100 80N

Reference 3022213.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 115
Resistance (ohm) 0,0071
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 42000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 375000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3900
Price List €382.77/pc