All Products

Fuse NH00 TY-gG 500V 16A

Reference 2000116.16.0 - Manufacturer SIBA
Class aM
Rated current In (A) 16
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 460
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 770
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 20A

Reference 2000116.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 770
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 1300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 25A

Reference 2000116.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 1500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 32A

Reference 2000116.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 4600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 35A

Reference 2000116.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,3
Melting I²t value (A²s) 3400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 5900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 40A

Reference 2000116.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 7900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 50A

Reference 2000116.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 4
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 11300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 63A

Reference 2000116.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 5
Melting I²t value (A²s) 9200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 15700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 80A

Reference 2000116.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 6
Melting I²t value (A²s) 13900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 23800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fusibile NH0 TY-gG 500V 25A

Reference 2000216.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 3
Melting I²t value (A²s) 1500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information

Fuse NH0 TY-gG 500V 32A

Reference 2000216.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 4600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information

Fuse NH0 TY-gG 500V 40A

Reference 2000216.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 4,3
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 7900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist