Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 150A

Reference 2002933.150.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 150
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 11200
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 59000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 160A

Reference 2002933.160.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 160
Applicable standards IEC, UL
Power loss (W) 30
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 11200
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 59000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 175A

Reference 2002933.175.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 175
Applicable standards IEC, UL
Power loss (W) 32
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 14900
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 98000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 50A

Reference 2002933.50.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 50
Applicable standards IEC, UL
Power loss (W) 14
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 360
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 63A

Reference 2002933.63.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 63
Applicable standards IEC, UL
Power loss (W) 15
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 900
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 7300
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 75A

Reference 2002933.75.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 75
Applicable standards IEC, UL
Power loss (W) 17
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 1400
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 4700
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing no ind. 80A

Reference 2002933.80.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 80
Applicable standards IEC, UL
Power loss (W) 18
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 1700
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 8900
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing with ind. 150A

Reference 2002934.150.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 150
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 11200
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 59000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing with ind. 160A

Reference 2002934.160.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 160
Applicable standards IEC, UL
Power loss (W) 30
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 11200
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 59000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing with ind. 175A

Reference 2002934.175.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 175
Applicable standards IEC, UL
Power loss (W) 32
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 14900
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 98000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH1XL 1100V DC gRL NH1XL screw fixing with ind. 50A

Reference 2002934.50.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 50
Applicable standards IEC, UL
Power loss (W) 14
Rated Voltage Un DC (V) 1100
Time costant L/R (ms) 10
Melting I²t value (A²s) 360
Voltage of total clearing I2t test 100000
Total clearing I²t @Un AC (A²s) 1900
Rated breaking capacity I1 AC (kA) 100000
Price List €750.01/pc
Quantity

Fuse NH00 TY-gG 500V 10A

Reference 2000116.10.0 - Manufacturer SIBA
Class aM
Rated current In (A) 10
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,8
Melting I²t value (A²s) 300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Class
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated insultaion voltage AC (V)
Rated insulated voltage DC (V)
Applicable standards
Product added to compare.
Product added to wishlist