Fuse NH00 TY-gG 500V 25A

Reference 2000116.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 1500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 32A

Reference 2000116.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 4600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 35A

Reference 2000116.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,3
Melting I²t value (A²s) 3400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 5900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 40A

Reference 2000116.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 7900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 50A

Reference 2000116.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 4
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 11300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 63A

Reference 2000116.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 5
Melting I²t value (A²s) 9200
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 15700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fuse NH00 TY-gG 500V 80A

Reference 2000116.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 6
Melting I²t value (A²s) 13900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 23800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 160
Product available on request Ask for more information

Fusibile NH0 TY-gG 500V 25A

Reference 2000216.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 3
Melting I²t value (A²s) 1500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information

Fuse NH0 TY-gG 500V 32A

Reference 2000216.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 4600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information

Fuse NH0 TY-gG 500V 40A

Reference 2000216.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH0
Applicable standards IEC
Power loss (W) 4,3
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 7900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 230
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 32A

Reference 2000316.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 3,6
Melting I²t value (A²s) 2600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 4600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information

Fuse NH1 TY-gG 500V 40A

Reference 2000316.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 4,3
Melting I²t value (A²s) 4600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 318
Total clearing I²t @Un AC (A²s) 7900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 290
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist