Fuses

Fuse NH1 gR 500VAC insulated 100A

Reference 2044104.100.0 - Manufacturer SIBA
Class aR
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 62
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 55000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 125A

Reference 2044104.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 53
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 42000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 160A

Reference 2044104.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2600
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 200A

Reference 2044104.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Price List €25.45/pc
Quantity

Fuse NH1 aR 500VAC insulated 224A

Reference 2044104.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 250A

Reference 2044104.250.0 - Manufacturer SIBA
Class gR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 22
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 gR 500VAC insulated 63A

Reference 2044104.63.0 - Manufacturer SIBA
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 33
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12300
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 gR 500VAC insulated 80A

Reference 2044104.80.0 - Manufacturer SIBA
Class gR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 27
Melting I²t value (A²s) 920
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 7600
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 100A

Reference 2044212.100.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 11
Melting I²t value (A²s) 21000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 91000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 125A

Reference 2044212.125.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 14
Melting I²t value (A²s) 35000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 180000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 160A

Reference 2044212.160.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 62000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 200A

Reference 2044212.200.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 19
Melting I²t value (A²s) 140000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 560000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.