Fuses

Fuse 5x20 T 250V glass UL-CSA 1,25A 7000176.1,25

Reference 179500.1,25.0 - Manufacturer SIBA
Class T
Rated current In (A) 1,25
Rated Voltage Un AC (V) 250
Power loss (W) 0,4
Voltage drop (mV) 300
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 19
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.41/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 1,5A 7000176.1,5

Reference 179500.1,5.0 - Manufacturer SIBA
Class T
Rated current In (A) 1,5
Rated Voltage Un AC (V) 250
Power loss (W) 0,5
Voltage drop (mV) 280
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 25
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.69/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 1,6A 7000176.1,6

Reference 179500.1,6.0 - Manufacturer SIBA
Class T
Rated current In (A) 1,6
Rated Voltage Un AC (V) 250
Power loss (W) 0,5
Voltage drop (mV) 270
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.41/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 1A 7000176.1

Reference 179500.1.0 - Manufacturer SIBA
Class T
Rated current In (A) 1
Rated Voltage Un AC (V) 250
Power loss (W) 0,4
Voltage drop (mV) 350
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 12
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 35
Weight (gr) 2
Price List €0.41/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 2,5A 7000176.2,5

Reference 179500.2,5.0 - Manufacturer SIBA
Class T
Rated current In (A) 2,5
Rated Voltage Un AC (V) 250
Power loss (W) 0,6
Voltage drop (mV) 215
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.41/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 2A 7000176.2

Reference 179500.2.0 - Manufacturer SIBA
Class T
Rated current In (A) 2
Rated Voltage Un AC (V) 250
Power loss (W) 0,5
Voltage drop (mV) 235
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 55
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.41/pc
Quantity

Fuse 5x20 T 250V glass UL-CSA 3A 7000176.3

Reference 179500.3.0 - Manufacturer SIBA
Class T
Rated current In (A) 3
Rated Voltage Un AC (V) 250
Power loss (W) 0,6
Voltage drop (mV) 200
Fuse Dimension (mm) 5x20
Melting I²t value (A²s) 160
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 250
Rated breaking capacity I1 AC (kA) 100
Weight (gr) 2
Price List €0.69/pc
Quantity

NR2A - Fuse DIN000 80mm aR 700VDC/690VAC no ind 25A

Reference 180.375.44.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 4,6
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 55
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 200
Rated breaking capacity I1 AC (kA) 200000
Price List €9.98/pc
Quantity

NR2A-Fuse 000/80 aR 700VDC/690VAC with ind. w/o lug 125A

Reference 180.801.43.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension 000
Applicable standards IEC
Power loss (W) 27,5
Rated Voltage Un DC (V) 700
Time costant L/R (ms) 2
Series name NR2A
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 2100
Fuse Connection/Terminal type Screw fixing
Fixing connection centres (mm) 80
Voltage of total clearing I2t test 700
Total clearing I²t @Un AC (A²s) 7700
Rated breaking capacity I1 AC (kA) 200000
Price List €13.22/pc
Quantity

E103 - Fuse 10x38 1000VDC aBAT 20A

Reference 180.809.48.0.0 - Manufacturer FAULTRAP
Class aBat
Rated current In (A) 20
Applicable standards IEC
Power loss (W) 2,6
Rated Voltage Un DC (V) 1000
Series name E103
Rated breaking capacity I1 DC (kA) 20000
Fuse Dimension (mm) 10x38
Fuse Connection/Terminal type Cylindrical
Product available on request Ask for more information

UR22 - Fuse 690V AC 22x58 fixing 80mm 100A

Reference 180.960.54.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Applicable standards IEC
Power loss (W) 19,1
Series name UR22
Melting I²t value (A²s) 2150
Fuse Connection/Terminal type Screw fixing
Total clearing I²t @Un AC (A²s) 9345
Rated breaking capacity I1 AC (kA) 200
Product available on request Ask for more information

Fuse 3/7,2kV 53x192 back-up with striker 80N 2A

Reference 1807002.0.0 - Manufacturer NIKDIM
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 7200
Applicable standards IEC
Power loss (W) 3
Resistance (ohm) 0,34
Fuse Dimension (mm) 53x192
Fuse Connection/Terminal type Cylindrical
Rated breaking capacity I1 AC (kA) 50000
Weight (gr) 1300
Price List €63.50/pc