Fuses

Fuse NH2 gR 500V with striker 100A

Reference 2001004.100.0 - Manufacturer SIBA
Class gR
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 23
Melting I²t value (A²s) 920
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 7600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 125A

Reference 2001004.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 29
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €397.10/pc
Quantity

Fuse NH2 aR 500V with striker 160A

Reference 2001004.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 40
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 200A

Reference 2001004.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 40
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €401.27/pc
Quantity

Fuse NH2 aR 500V with striker 224A

Reference 2001004.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 44
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €414.22/pc
Quantity

Fuse NH2 aR 500V with striker 250A

Reference 2001004.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 51
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 51000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €68.46/pc
Quantity

Fuse NH2 aR 500V with striker 315A

Reference 2001004.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 69
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 84000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €71.09/pc
Quantity

Fuse NH2 gR 500V with striker 32A

Reference 2001004.32.0 - Manufacturer SIBA
Class gR
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 7,4
Melting I²t value (A²s) 67
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 550
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 355A

Reference 2001004.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 81
Melting I²t value (A²s) 20000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 125000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €468.77/pc
Quantity

Fuse NH2 gR 500V with striker 40A

Reference 2001004.40.0 - Manufacturer SIBA
Class gR
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 9,2
Melting I²t value (A²s) 90
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 740
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information

Fuse NH2 aR 500V with striker 400A

Reference 2001004.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 94
Melting I²t value (A²s) 27000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 155000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €75.37/pc
Quantity

Fuse NH2 gR 500V with striker 50A

Reference 2001004.50.0 - Manufacturer SIBA
Class gR
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 11,5
Melting I²t value (A²s) 190
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1560
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist