Fuses

Fuse NH4 gG 500V with striker 630A

Reference 2001213.630.0 - Manufacturer SIBA
Class aM
Rated current In (A) 630
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 49
Melting I²t value (A²s) 1950000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 4840000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 710A

Reference 2001213.710.0 - Manufacturer SIBA
Class aM
Rated current In (A) 710
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 800A

Reference 2001213.800.0 - Manufacturer SIBA
Class aM
Rated current In (A) 800
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Power loss (W) 66
Melting I²t value (A²s) 3700000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 8900000
Rated breaking capacity I1 AC (kA) 120000
Price List €147.34/pc
Quantity

Fuse NH4 gG 500V with striker 850A

Reference 2001213.850.0 - Manufacturer SIBA
Class aM
Rated current In (A) 850
Rated Voltage Un AC (V) 500
Dimension NH4
Applicable standards IEC
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Rated breaking capacity I1 AC (kA) 120000
Price List €159.57/pc
Quantity

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 160A

Reference 2001927.160.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 160
Dimension SQB1
Applicable standards IEC
Power loss (W) 36
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 25000
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 175A

Reference 2001927.175.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 175
Dimension SQB1
Applicable standards IEC
Power loss (W) 37
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 31500
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 200A

Reference 2001927.200.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 200
Dimension SQB1
Applicable standards IEC
Power loss (W) 43
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 14300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 47000
Price List €3,520.19/pc
Quantity

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 50A

Reference 2001927.50.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 50
Dimension SQB1
Applicable standards IEC
Power loss (W) 17
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 270
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 900
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 63A

Reference 2001927.63.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 63
Dimension SQB1
Applicable standards IEC
Power loss (W) 20
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 6600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 2000
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 80A

Reference 2001927.80.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 80
Dimension SQB1
Applicable standards IEC
Power loss (W) 23
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 1100
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 4000
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC 160A

Reference 2001928.160.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 160
Dimension SQB1
Applicable standards IEC
Power loss (W) 36
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 25000
Product available on request Ask for more information

Fuse SQB1 screw M8 gPV 1100VDC 175A

Reference 2001928.175.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 175
Dimension SQB1
Applicable standards IEC
Power loss (W) 37
Rated Voltage Un DC (V) 1100
Rated breaking capacity I1 DC (kA) 30000
Fixing dimensions M8
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1100
Total clearing I²t @Un AC (A²s) 31500
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist