Fuse NH2 gG 500V with striker 400A

Reference 2001013.400.0 - Manufacturer SIBA
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 32
Melting I²t value (A²s) 200800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 859000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 660
Price List €301.88/pc
Quantity

Fuse NH2 gG 500V with striker 50A

Reference 2001013.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 13600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 63A

Reference 2001013.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 5,8
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 26400
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €28.87/pc
Quantity

Fuse NH2 gG 500V with striker 80A

Reference 2001013.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC
Power loss (W) 6,5
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €253.53/pc
Quantity

Fuse NH3 aR 500V with striker 160A

Reference 2001104.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 48
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 200A

Reference 2001104.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 56
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Price List €637.74/pc
Quantity

Fuse NH3 aR 500V with striker 224A

Reference 2001104.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 61
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 250A

Reference 2001104.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 65
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 51000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fusibile NH3 aR 500V with striker 315A

Reference 2001104.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 76
Melting I²t value (A²s) 14000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 84000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Price List €639.72/pc
Quantity

Fuse NH3 aR 500V with striker 355A

Reference 2001104.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 83
Melting I²t value (A²s) 20000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 125000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920
Product available on request Ask for more information

Fuse NH3 aR 500V with striker 400A

Reference 2001104.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 85
Melting I²t value (A²s) 27000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 155000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 930
Price List €700.82/pc
Quantity

Fuse NH3 aR 500V with striker 450A

Reference 2001104.450.0 - Manufacturer SIBA
Class aR
Rated current In (A) 450
Rated Voltage Un AC (V) 500
Dimension NH3
Applicable standards IEC
Power loss (W) 90
Melting I²t value (A²s) 38000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 190000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 920