Fuses

Fuse NH3L 1350V gRL(gS) with indicator 400A

Reference 2074534.400.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 400
Rated Voltage Un AC (V) 1350
Dimension NH3L
Applicable standards IEC
Power loss (W) 55
Melting I²t value (A²s) 135000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1500000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH3L 1350V gRL(gS) with indicator 450A

Reference 2074534.450.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 450
Rated Voltage Un AC (V) 1350
Dimension NH3L
Applicable standards IEC
Power loss (W) 60
Melting I²t value (A²s) 190000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 2110000
Rated breaking capacity I1 AC (kA) 100000
Price List €313.89/pc
Quantity

Fuse NH3L 1350V gRL(gS) with indicator 80A

Reference 2074534.80.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 80
Rated Voltage Un AC (V) 1350
Dimension NH3L
Applicable standards IEC
Power loss (W) 17
Melting I²t value (A²s) 2800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 30000
Rated breaking capacity I1 AC (kA) 100000
Price List €1,081.25/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 100A

Reference 2074634.100.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 100
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 21
Melting I²t value (A²s) 3700
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 40000
Rated breaking capacity I1 AC (kA) 100000
Price List €1,185.37/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 125A

Reference 2074634.125.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 125
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 25
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 65000
Rated breaking capacity I1 AC (kA) 100000
Price List €1,196.22/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 160A

Reference 2074634.160.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 160
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 29
Melting I²t value (A²s) 11300
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 130000
Rated breaking capacity I1 AC (kA) 100000
Price List €316.89/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 200A

Reference 2074634.200.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 200
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 32
Melting I²t value (A²s) 25000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Price List €333.95/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 225A

Reference 2074634.225.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 225
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 36
Melting I²t value (A²s) 30000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 335000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 250A

Reference 2074634.250.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 250
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 38
Melting I²t value (A²s) 45000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 500000
Rated breaking capacity I1 AC (kA) 100000
Price List €321.21/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 315A

Reference 2074634.315.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 315
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 48
Melting I²t value (A²s) 70000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 780000
Rated breaking capacity I1 AC (kA) 100000
Price List €1,292.44/pc
Quantity

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 350A

Reference 2074634.350.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 350
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 53
Melting I²t value (A²s) 95000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1055000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse SQB3 1350V gRL(gS) fixing dist. 167mm 400A

Reference 2074634.400.0 - Manufacturer SIBA
Class gRL, gS
Rated current In (A) 400
Rated Voltage Un AC (V) 1350
Dimension SQB3
Applicable standards IEC
Power loss (W) 55
Melting I²t value (A²s) 135000
Fuse Connection/Terminal type Screw fixing
Voltage of total clearing I2t test 1500
Total clearing I²t @Un AC (A²s) 1500000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist