Fuses

Fuse NH2 gR 500V top indicator 32A

Reference 2000404.32.0 - Manufacturer SIBA
Class gR
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 7,4
Melting I²t value (A²s) 67
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 550
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €748.62/pc
Quantity

Fuse NH2 aR 500V top indicator 355A

Reference 2000404.355.0 - Manufacturer SIBA
Class aR
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 81
Melting I²t value (A²s) 20000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 125000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 620
Price List €126.41/pc
Quantity

Fuse NH2 gR 500V top indicator 40A

Reference 2000404.40.0 - Manufacturer SIBA
Class gR
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 9,2
Melting I²t value (A²s) 90
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 740
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €97.69/pc
Quantity

Fuse NH2 aR 500V top indicator 400A

Reference 2000404.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 94
Melting I²t value (A²s) 27000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 155000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €56.55/pc
Quantity

Fuse NH2 aR 500V top indicator 450A

Reference 2000404.450.0 - Manufacturer SIBA
Class aR
Rated current In (A) 450
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 105
Melting I²t value (A²s) 38000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 219000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €166.79/pc
Quantity

Fuse NH2 gR 500V top indicator 50A

Reference 2000404.50.0 - Manufacturer SIBA
Class gR
Rated current In (A) 50
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 11,5
Melting I²t value (A²s) 190
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1560
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 650
Price List €753.57/pc
Quantity

Fuse NH2 aR 500V top indicator 500A

Reference 2000404.500.0 - Manufacturer SIBA
Class aR
Rated current In (A) 500
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 117
Melting I²t value (A²s) 47000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 271000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €174.19/pc
Quantity

Fuse NH2 aR 500V top indicator 550A

Reference 2000404.550.0 - Manufacturer SIBA
Class aR
Rated current In (A) 550
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 125
Melting I²t value (A²s) 57000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 328000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €126.17/pc
Quantity

Fuse NH2 gR 500V top indicator 63A

Reference 2000404.63.0 - Manufacturer SIBA
Class gR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 14.5
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2700
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 400
Price List €754.39/pc
Quantity

Fuse NH2 aR 500V top indicator 630A

Reference 2000404.630.0 - Manufacturer SIBA
Class aR
Rated current In (A) 630
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 142
Melting I²t value (A²s) 80000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 460000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 610
Price List €212.65/pc
Quantity

Fuse NH2 gR 500V top indicator 80A

Reference 2000404.80.0 - Manufacturer SIBA
Class gR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 18
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 400
Price List €39.35/pc
Quantity

Fuse NH2 500V Ty with top indicator 100A

Reference 2000412.100.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Rated breaking capacity I1 AC (kA) 100000
Weight (gr) 610
Price List €66.02/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist