Fuses

Fuse NH2 500V Ty with top indicator and insulated cover 160A

Reference 2044212.160.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 16
Melting I²t value (A²s) 62000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 200A

Reference 2044212.200.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 19
Melting I²t value (A²s) 140000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 560000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 224A

Reference 2044212.224.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 21
Melting I²t value (A²s) 180000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 790000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 250A

Reference 2044212.250.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 24
Melting I²t value (A²s) 220000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 960000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 315A

Reference 2044212.315.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 315
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 27
Melting I²t value (A²s) 380000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 1800000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 355A

Reference 2044212.355.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 355
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 32
Melting I²t value (A²s) 490000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2200000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 63A

Reference 2044212.63.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 7,6
Melting I²t value (A²s) 7100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 31000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 80A

Reference 2044212.80.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 9,1
Melting I²t value (A²s) 12000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 52000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH00 gG 500V double indicator 25A

Reference 2044513.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 205
Price List €48.31/pc
Quantity

Fuse NH00 gG 500V double indicator 32A

Reference 2044513.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 3,1
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 5800
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH00 gG 500V double indicator 40A

Reference 2044513.40.0 - Manufacturer SIBA
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 4
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 11500
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse 400V NH000 gG insulated cover plate 10A

Reference 2044713.10.0 - Manufacturer SIBA
Class gG
Rated current In (A) 10
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 240
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 695
Rated breaking capacity I1 AC (kA) 120000
Price List €28.96/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 100A

Reference 2044713.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 6
Melting I²t value (A²s) 24500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 94000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 16A

Reference 2044713.16.0 - Manufacturer SIBA
Class gG
Rated current In (A) 16
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,5
Melting I²t value (A²s) 410
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 810
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 20A

Reference 2044713.20.0 - Manufacturer SIBA
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,2
Melting I²t value (A²s) 690
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 1550
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 25A

Reference 2044713.25.0 - Manufacturer SIBA
Class gG
Rated current In (A) 25
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 2,3
Melting I²t value (A²s) 1400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 3000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 32A

Reference 2044713.32.0 - Manufacturer SIBA
Class gG
Rated current In (A) 32
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,1
Melting I²t value (A²s) 2950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 5800
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 35A

Reference 2044713.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,3
Melting I²t value (A²s) 3450
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 7750
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 40A

Reference 2044713.40.0 - Manufacturer SIBA
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,5
Melting I²t value (A²s) 5600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 11500
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 50A

Reference 2044713.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 3,9
Melting I²t value (A²s) 6450
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 18000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 6A

Reference 2044713.6.0 - Manufacturer SIBA
Class gG
Rated current In (A) 6
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 1,9
Melting I²t value (A²s) 70
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 240
Rated breaking capacity I1 AC (kA) 120000
Price List €28.96/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 63A

Reference 2044713.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 4,2
Melting I²t value (A²s) 9950
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 32000
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH000 gG insulated cover plate 80A

Reference 2044713.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 400
Dimension NH000
Applicable standards IEC
Power loss (W) 5,1
Melting I²t value (A²s) 15500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 47500
Rated breaking capacity I1 AC (kA) 120000
Price List €13.93/pc
Quantity

Fuse 400V NH00 gG insulated cover plate 125A

Reference 2044813.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 400
Dimension NH00
Applicable standards IEC
Power loss (W) 8,7
Melting I²t value (A²s) 43000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 150000
Rated breaking capacity I1 AC (kA) 120000
Price List €18.34/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist