Fuses

Fuse NH1 AC 690V aM 120 kA 20A insulated cover

Reference 2045508.20.0 - Manufacturer SIBA
Class aM
Rated current In (A) 20
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 1,1
Melting I²t value (A²s) 921
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 3500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Product available on request Ask for more information

Fuse NH1 AC 690V aM 120 kA 224A insulated cover

Reference 2045508.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 16
Melting I²t value (A²s) 132000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 500000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Product available on request Ask for more information

Fuse NH1 AC 690V aM 120 kA insulated cover

Reference 2045508.32.0 - Manufacturer SIBA
Class aM
Rated current In (A) 32
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 1,6
Melting I²t value (A²s) 2430
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 9300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 35A insulated cover

Reference 2045608.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 2,29
Melting I²t value (A²s) 2820
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 40A insulated cover

Reference 2045608.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 2,65
Melting I²t value (A²s) 3680
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 400A insulated cover

Reference 2045608.400.0 - Manufacturer SIBA
Class aM
Rated current In (A) 400
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 27
Melting I²t value (A²s) 623000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 2350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 50A insulated cover

Reference 2045608.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 3,04
Melting I²t value (A²s) 7290
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 28000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse NH2 AC 690V aM 120 kA 63A insulated cover

Reference 2045608.63.0 - Manufacturer SIBA
Class aM
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 4,14
Melting I²t value (A²s) 10400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 39000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 125A

Reference 2054427.125.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 125
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 3700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 14200
Weight (gr) 2100
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 315A

Reference 2054427.315.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 315
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 53
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 28000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 92000
Weight (gr) 2100
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 50A

Reference 2054427.50.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 50
Dimension SQB1
Applicable standards IEC, UL
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Weight (gr) 2100
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 63A

Reference 2054427.63.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 63
Dimension SQB1
Applicable standards IEC, UL
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Weight (gr) 2100
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 70A

Reference 2054427.70.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 70
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 15
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 870
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 3300
Weight (gr) 2100
Product available on request Ask for more information

Fuse SQB1 1000VDC gPV with switch adapter 90A

Reference 2054427.90.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 90
Dimension SQB1
Applicable standards IEC, UL
Power loss (W) 21
Rated Voltage Un DC (V) 1000
Rated breaking capacity I1 DC (kA) 30000
Melting I²t value (A²s) 1300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 5000
Weight (gr) 2100
Product available on request Ask for more information

Fuse NH1 gR 500VAC insulated 100A

Reference 2044104.100.0 - Manufacturer SIBA
Class aR
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 62
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 55000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 125A

Reference 2044104.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 53
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 42000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 160A

Reference 2044104.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2600
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 200A

Reference 2044104.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Price List €25.45/pc
Quantity

Fuse NH1 aR 500VAC insulated 224A

Reference 2044104.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 aR 500VAC insulated 250A

Reference 2044104.250.0 - Manufacturer SIBA
Class gR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 22
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 gR 500VAC insulated 63A

Reference 2044104.63.0 - Manufacturer SIBA
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 33
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12300
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH1 gR 500VAC insulated 80A

Reference 2044104.80.0 - Manufacturer SIBA
Class gR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 27
Melting I²t value (A²s) 920
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 7600
Rated breaking capacity I1 AC (kA) 120000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 100A

Reference 2044212.100.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 11
Melting I²t value (A²s) 21000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 91000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information

Fuse NH2 500V Ty with top indicator and insulated cover 125A

Reference 2044212.125.0 - Manufacturer SIBA
Class Ty
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH2
Power loss (W) 14
Melting I²t value (A²s) 35000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 180000
Rated breaking capacity I1 AC (kA) 100000
Product available on request Ask for more information
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist