Fuses

Fuse NH00 gG 500V with striker 80A

Reference 2000713.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH00
Applicable standards IEC
Power loss (W) 5,4
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 45500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 190
Price List €39.61/pc
Quantity

Fuse NH1 aR 500V with striker 125A

Reference 2000904.125.0 - Manufacturer SIBA
Class aR
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Applicable standards IEC
Power loss (W) 33
Melting I²t value (A²s) 1660
Fuse Connection/Terminal type NH knife contact
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 12300
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €121.91/pc
Quantity

Fuse NH1 aR 500V with striker 160A

Reference 2000904.160.0 - Manufacturer SIBA
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 2400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 19500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €54.55/pc
Quantity

Fuse NH1 aR 500V with striker 200A

Reference 2000904.200.0 - Manufacturer SIBA
Class aR
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 40
Melting I²t value (A²s) 5800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 37000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €59.61/pc
Quantity

Fuse NH1 aR 500V with striker 224A

Reference 2000904.224.0 - Manufacturer SIBA
Class aR
Rated current In (A) 224
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 53
Melting I²t value (A²s) 7600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 42000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €155.51/pc
Quantity

Fuse NH1 aR 500V with striker 250A

Reference 2000904.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 62
Melting I²t value (A²s) 9600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 55000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €61.37/pc
Quantity

Fuse NH1 aR 500V with striker 63A

Reference 2000904.63.0 - Manufacturer SIBA
Class aR
Rated current In (A) 63
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 330
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 2600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €120.88/pc
Quantity

Fuse NH1 aR 500V with striker 80A

Reference 2000904.80.0 - Manufacturer SIBA
Class aR
Rated current In (A) 80
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 22
Melting I²t value (A²s) 510
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 4200
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €121.07/pc
Quantity

Fuse NH1 gG 500V with striker 100A

Reference 2000913.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 88600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €209.56/pc
Quantity

Fuse NH1 gG 500V with striker 125A

Reference 2000913.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 127500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €209.56/pc
Quantity

Fuse NH1 gG 500V with striker 160A

Reference 2000913.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 12,8
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 226600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €209.57/pc
Quantity

Fuse NH1 gG 500V with striker 200A

Reference 2000913.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 500
Dimension NH1
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 440
Total clearing I²t @Un AC (A²s) 390900
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 410
Price List €221.49/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist