Fuses

Fuse NH1 aR 1000VAC-800VDC 350A

Reference 2041332.350.0 - Manufacturer SIBA
Class aR
Rated current In (A) 350
Rated Voltage Un AC (V) 1000
Dimension NH1
Applicable standards IEC, UL
Power loss (W) 22
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 13500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 85000
Rated breaking capacity I1 AC (kA) 120000
Price List €111.66/pc
Quantity

Fuse NH1 aR 1000VAC-800VDC 400A

Reference 2041332.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 1000
Dimension NH1
Applicable standards IEC, UL
Power loss (W) 24
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 39000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 230000
Rated breaking capacity I1 AC (kA) 120000
Price List €116.04/pc
Quantity

Fuse NH1 aR 1000VAC-800VDC 450A

Reference 2041332.450.0 - Manufacturer SIBA
Class aR
Rated current In (A) 450
Rated Voltage Un AC (V) 1000
Dimension NH1
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 47000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 280000
Rated breaking capacity I1 AC (kA) 120000
Price List €111.64/pc
Quantity

Fuse NH1 aR 1000VAC-800VDC 500A

Reference 2041332.500.0 - Manufacturer SIBA
Class aR
Rated current In (A) 500
Rated Voltage Un AC (V) 1000
Dimension NH1
Applicable standards IEC, UL
Power loss (W) 27
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 65000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 400000
Rated breaking capacity I1 AC (kA) 120000
Price List €836.31/pc
Quantity

Fuse NH1 aR 1000VAC-800VDC 550A

Reference 2041332.550.0 - Manufacturer SIBA
Class aR
Rated current In (A) 550
Rated Voltage Un AC (V) 1000
Dimension NH1
Applicable standards IEC, UL
Power loss (W) 29
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 84000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 550000
Rated breaking capacity I1 AC (kA) 120000
Price List €838.54/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 250A

Reference 2041432.250.0 - Manufacturer SIBA
Class aR
Rated current In (A) 250
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 17
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 7800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 45000
Rated breaking capacity I1 AC (kA) 120000
Price List €125.58/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 315A

Reference 2041432.315.0 - Manufacturer SIBA
Class aR
Rated current In (A) 315
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 20
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 12600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 80000
Rated breaking capacity I1 AC (kA) 120000
Price List €132.96/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 350A

Reference 2041432.350.0 - Manufacturer SIBA
Class aR
Rated current In (A) 350
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 22
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 18500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Price List €133.13/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 400A

Reference 2041432.400.0 - Manufacturer SIBA
Class aR
Rated current In (A) 400
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 25
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 26500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 160000
Rated breaking capacity I1 AC (kA) 120000
Price List €132.76/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 450A

Reference 2041432.450.0 - Manufacturer SIBA
Class aR
Rated current In (A) 450
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 27
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 33500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 210000
Rated breaking capacity I1 AC (kA) 120000
Price List €1,003.70/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 500A

Reference 2041432.500.0 - Manufacturer SIBA
Class aR
Rated current In (A) 500
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 29
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 50000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 300000
Rated breaking capacity I1 AC (kA) 120000
Price List €132.72/pc
Quantity

Fuse NH2 aR 1000VAC-800VDC 550A

Reference 2041432.550.0 - Manufacturer SIBA
Class aR
Rated current In (A) 550
Rated Voltage Un AC (V) 1000
Dimension NH2
Applicable standards IEC, UL
Power loss (W) 32
Rated Voltage Un DC (V) 800
Melting I²t value (A²s) 74000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 1000
Total clearing I²t @Un AC (A²s) 440000
Rated breaking capacity I1 AC (kA) 120000
Price List €1,107.42/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist