Fuse NH1 gG 690V insulated cover double indicator 35A

Reference 2045513.35.0 - Manufacturer SIBA
Class gG
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,2
Melting I²t value (A²s) 3100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 8500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 40A

Reference 2045513.40.0 - Manufacturer SIBA
Class gG
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 4,7
Melting I²t value (A²s) 4700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 12500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 50A

Reference 2045513.50.0 - Manufacturer SIBA
Class gG
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 5,5
Melting I²t value (A²s) 5900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 15000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 63A

Reference 2045513.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 6.3
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 21600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.36/pc
Quantity

Fuse NH1 gG 690V insulated cover double indicator 80A

Reference 2045513.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 7,3
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 40000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €30.37/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 100A insulated cover

Reference 2045608.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 6,65
Melting I²t value (A²s) 29100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 125A insulated cover

Reference 2045608.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8,54
Melting I²t value (A²s) 46700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 178000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 160A insulated cover

Reference 2045608.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 74600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 285000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.67/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 200A insulated cover

Reference 2045608.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 111000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 420000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.68/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 224A insulated cover

Reference 2045608.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16
Melting I²t value (A²s) 132000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 500000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.70/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 250A insulated cover

Reference 2045608.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 20
Melting I²t value (A²s) 167000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 640000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €48.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 315A insulated cover

Reference 2045608.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 24
Melting I²t value (A²s) 298000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €49.15/pc