Fuses

Fuse NH00 gG 690V insulated cover double indicator 63A

Reference 2045313.63.0 - Manufacturer SIBA
Class gG
Rated current In (A) 63
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 5,6
Melting I²t value (A²s) 10300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 21600
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 210
Price List €18.17/pc
Quantity

Fuse NH00 gG 690V insulated cover double indicator 80A

Reference 2045313.80.0 - Manufacturer SIBA
Class gG
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH00
Applicable standards IEC
Power loss (W) 6.3
Melting I²t value (A²s) 17300
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 40000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 186
Price List €18.17/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 100A insulated cover

Reference 2045508.100.0 - Manufacturer SIBA
Class aM
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 6
Melting I²t value (A²s) 29100
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 110000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €31.39/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 125A insulated cover

Reference 2045508.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 7,8
Melting I²t value (A²s) 46700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 178000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €32.32/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 16A insulated cover

Reference 2045508.16.0 - Manufacturer SIBA
Class aM
Rated current In (A) 16
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 1
Melting I²t value (A²s) 476
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €31.57/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 160A insulated cover

Reference 2045508.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 10
Melting I²t value (A²s) 74600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 285000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €32.33/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 200A insulated cover

Reference 2045508.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 111000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 420000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €36.93/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 25A insulated cover

Reference 2045508.25.0 - Manufacturer SIBA
Class aM
Rated current In (A) 25
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 1,4
Melting I²t value (A²s) 1441
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 5500
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €87.83/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 250A insulated cover

Reference 2045508.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 18
Melting I²t value (A²s) 167000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 640000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €36.95/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 35A insulated cover

Reference 2045508.35.0 - Manufacturer SIBA
Class aM
Rated current In (A) 35
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 2,1
Melting I²t value (A²s) 2820
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 11000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €31.37/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 40A insulated cover

Reference 2045508.40.0 - Manufacturer SIBA
Class aM
Rated current In (A) 40
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 2,4
Melting I²t value (A²s) 3680
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 14000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €31.21/pc
Quantity

Fuse NH1 AC 690V aM 120 kA 50A insulated cover

Reference 2045508.50.0 - Manufacturer SIBA
Class aM
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Dimension NH1
Applicable standards IEC
Power loss (W) 2,8
Melting I²t value (A²s) 7290
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 28000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 430
Price List €31.37/pc