Fuses

Fuse NH2 AC 690V aM 120 kA 125A insulated cover

Reference 2045608.125.0 - Manufacturer SIBA
Class aM
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8,54
Melting I²t value (A²s) 46700
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 178000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 160A insulated cover

Reference 2045608.160.0 - Manufacturer SIBA
Class aM
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 74600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 285000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.67/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 200A insulated cover

Reference 2045608.200.0 - Manufacturer SIBA
Class aM
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 15
Melting I²t value (A²s) 111000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 420000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.68/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 224A insulated cover

Reference 2045608.224.0 - Manufacturer SIBA
Class aM
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16
Melting I²t value (A²s) 132000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 500000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.70/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 250A insulated cover

Reference 2045608.250.0 - Manufacturer SIBA
Class aM
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 20
Melting I²t value (A²s) 167000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 640000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €48.65/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 315A insulated cover

Reference 2045608.315.0 - Manufacturer SIBA
Class aM
Rated current In (A) 315
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 24
Melting I²t value (A²s) 298000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1150000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €49.15/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 355A insulated cover

Reference 2045608.355.0 - Manufacturer SIBA
Class aM
Rated current In (A) 355
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 25
Melting I²t value (A²s) 446000
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 1700000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €49.17/pc
Quantity

Fuse NH2 AC 690V aM 120 kA 80A insulated cover

Reference 2045608.80.0 - Manufacturer SIBA
Class aM
Rated current In (A) 80
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 5,28
Melting I²t value (A²s) 17800
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 690
Total clearing I²t @Un AC (A²s) 68000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 460
Price List €47.65/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 100A

Reference 2045613.100.0 - Manufacturer SIBA
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8,6
Melting I²t value (A²s) 28900
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 75000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 440
Price List €39.14/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 125A

Reference 2045613.125.0 - Manufacturer SIBA
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 11
Melting I²t value (A²s) 44400
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 120000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.42/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 160A

Reference 2045613.160.0 - Manufacturer SIBA
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 14
Melting I²t value (A²s) 78500
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 240000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.43/pc
Quantity

Fuse NH2 gG 690V insulated cover double indicator 200A

Reference 2045613.200.0 - Manufacturer SIBA
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 16,5
Melting I²t value (A²s) 157600
Fuse Connection/Terminal type NH knife
Voltage of total clearing I2t test 500
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 450
Price List €41.44/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.