Fuse 12kV 53x442 back-up with striker 4A 80N

Reference 3010113.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 0,52
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 40A 80N

Reference 3010113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 45
Resistance (ohm) 0,022
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 19000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Price List €184.79/pc
Quantity

Fuse 12kV 53x442 back-up with striker 5A 80N

Reference 3010113.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 8,3
Resistance (ohm) 0,236
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2300
Product available on request Ask for more information

Fuse 12kV 53x442 back-up with striker 50A 80N

Reference 3010113.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 6000
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 0,016
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 5220
Total clearing I²t @Un AC (A²s) 36000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Price List €190.49/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 100A 80N

Reference 3002093.100.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 100
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 108
Resistance (ohm) 7,7
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 23500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 183000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €559.64/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 50A 80N

Reference 3002093.50.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 50
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 42
Resistance (ohm) 15
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 5500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €456.59/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 63A 80N

Reference 3002093.63.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 63
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 54
Resistance (ohm) 12
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 8500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 68000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €488.85/pc
Quantity

Fuse 12kV 85x292 general purpose with striker 80A 80N

Reference 3002093.80.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 79
Resistance (ohm) 9
Fuse Dimension (mm) 85x292
Melting I²t value (A²s) 16200
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 142000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3880
Price List €511.94/pc
Quantity

Fuse NH2 690V gG 100A

Reference 3002100.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 8.2
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 125A

Reference 3002125.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 9,3
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 160A

Reference 3002160.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 12.5
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse NH2 690V gG 200A

Reference 3002200.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 200
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 15,9
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse 24kV 85x442 back-up with striker 100ARC85 80N

Reference 3002213.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 141
Resistance (ohm) 0,013
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 28000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 254000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5760
Price List €181.92/pc
Quantity

Fuse 24kV 85x442 back-up with striker 125ARC90 80N

Reference 3002213.125.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 125
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 136
Resistance (ohm) 0,011
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 38400
Minimum breaking current (A) 390
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 348000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5720
Price List €257.93/pc
Quantity

Fuse 24kV 85x442 back-up with striker 160ARC105 80N

Reference 3002213.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 146
Resistance (ohm) 0,0088
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 62000
Minimum breaking current (A) 600
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 378000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5700
Price List €531.40/pc
Quantity

Fuse 24kV 85x442 striker no temp-limiting 100ARC85 120N

Reference 3002214.100.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Power loss (W) 234
Resistance (ohm) 13
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 33000
Minimum breaking current (A) 320
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 210000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 5710
Price List €229.29/pc
Quantity

Fuse 24kV 85x442 striker no temp-limiting 160A 120N

Reference 3002214.160.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 160
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 85x442
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5600
Price List €545.58/pc
Quantity

Fuse 24kV 87x442 striker no temp.lim 200ARC112 120N

Reference 3002214.200.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 200
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 172
Resistance (ohm) 0,0093
Fuse Dimension (mm) 87x442
Melting I²t value (A²s) 75000
Minimum breaking current (A) 800
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 313000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 6320
Price List €574.92/pc
Quantity

Fuse 24kV 87x442 striker no temp.lim 250ARC125 120N

Reference 3002214.250LM.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 250
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 142
Resistance (ohm) 0,006
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 179000
Minimum breaking current (A) 1000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 803000
Rated breaking capacity I1 AC (kA) 63000
Price List €595.57/pc
Quantity

Fuse NH2 690V gG 224A

Reference 3002224.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 224
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 18,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information

Fuse 24 kV 85x442 SSK with striker 100A 80N

Reference 3002243.100.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 100
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 188
Resistance (ohm) 12
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 22300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 136000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €393.24/pc
Quantity

Fuse 24 kV 85x442 SSK with striker 125A 80N

Reference 3002243.125.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 125
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 277
Resistance (ohm) 10
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 30300
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 248000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €433.60/pc
Quantity

Fuse 24 kV 85x442 SSK with striker 140A 80N

Reference 3002243.140.0 - Manufacturer SIBA
Class HH SSK
Rated current In (A) 140
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 155
Resistance (ohm) 8
Fuse Dimension (mm) 85x442
Melting I²t value (A²s) 51000
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 24000
Total clearing I²t @Un AC (A²s) 350000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 5820
Price List €356.15/pc
Quantity

Fuse NH2 690V gG 250A

Reference 3002250.0.0 - Manufacturer NIKDIM
Class gG
Rated current In (A) 250
Rated Voltage Un AC (V) 690
Dimension NH2
Applicable standards IEC
Power loss (W) 20,4
Fuse Connection/Terminal type NH knife
Rated breaking capacity I1 AC (kA) 120000
Weight (gr) 585
Product available on request Ask for more information