Fuses

Fuse 17,5kV 53X442 back-up 0,5A

Reference 3023111.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 8,1
Resistance (ohm) 29,48
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Price List €97.06/pc
Quantity

Fuse 17,5kV 53X442 back-up 1A

Reference 3023111.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 6,2
Resistance (ohm) 4,64
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 1,8
Rated breaking capacity I1 AC (kA) 63000
Product available on request Ask for more information

Fuse 17,5kV 67x442 back-up with striker 10A 80N

Reference 3023113.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 35
Resistance (ohm) 0,256
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 680
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €496.61/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 16A 80N

Reference 3023113.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 43
Resistance (ohm) 0,123
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 2400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €659.35/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 2,15 80N

Reference 3023113.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 12
Resistance (ohm) 1,4
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 24
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Product available on request Ask for more information

Fuse 17,5kV 67x442 back-up with striker 2A 80N

Reference 3023113.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 2,06
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Price List €413.95/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 20A 80N

Reference 3023113.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 34
Resistance (ohm) 0,062
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 545
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 4400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €503.12/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 25A 80N

Reference 3023113.25.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 25
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 41
Resistance (ohm) 0,048
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 920
Minimum breaking current (A) 90
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 5400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €507.18/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 3,15A 80N

Reference 3023113.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 13
Resistance (ohm) 0,92
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2340
Price List €133.53/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 31,5A 80N

Reference 3023113.31,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 31,5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 53
Resistance (ohm) 0,039
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 1400
Minimum breaking current (A) 110
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 9800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €513.80/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 4A 80N

Reference 3023113.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 16
Resistance (ohm) 0,69
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Product available on request Ask for more information

Fuse 17,5kV 67x442 back-up with striker 40A 80N

Reference 3023113.40.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 40
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 65
Resistance (ohm) 0,029
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 2500
Minimum breaking current (A) 140
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 17500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2360
Price List €534.81/pc
Quantity

Fuse 17,5kV 67x442 back-up with striker 5A 80N

Reference 3023113.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 11
Resistance (ohm) 0,314
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Product available on request Ask for more information

Fuse 17,5kV 67x442 back-up with striker 6,3A 80N

Reference 3023113.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 21
Resistance (ohm) 0,402
Fuse Dimension (mm) 53x442
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 520
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2280
Price List €209.74/pc
Quantity

Fuse 17,5kV 85x442 back-up with striker 50A 80N

Reference 3023213.50.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 50
Rated Voltage Un AC (V) 17500
Applicable standards IEC
Power loss (W) 74
Resistance (ohm) 0,021
Fuse Dimension (mm) 67x442
Melting I²t value (A²s) 4700
Minimum breaking current (A) 170
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 15225
Total clearing I²t @Un AC (A²s) 33000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 3710
Price List €616.27/pc
Quantity

Fuse 24kV 53x292 TV no striker 0,5A

Reference 3018011.0,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 11,2
Resistance (ohm) 40,55
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 1,6
Minimum breaking current (A) 5
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 5,9
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €71.27/pc
Quantity

Fuse 24kV 53x292 TV no striker 0,8A

Reference 3018011.0,8.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 0,8
Rated Voltage Un AC (V) 2400
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 2400
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €29.61/pc
Quantity

Fuse 24kV 53x292 TV no striker 1A

Reference 3018011.1.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 1
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 8,6
Resistance (ohm) 6,45
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 0,63
Minimum breaking current (A) 8
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 1,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €90.44/pc
Quantity

Fuse 24kV 53x292 TV without striker 2A

Reference 3018011.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1700
Price List €90.54/pc
Quantity

Fuse 24kV 53x292 TV without striker 4A

Reference 3018011.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Fuse Dimension (mm) 53x292
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €90.95/pc
Quantity

Fuse 24kV 53x292 back-up with striker 10A 80N

Reference 3018013.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 52
Resistance (ohm) 0,352
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 880
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €131.03/pc
Quantity

Fuse 24kV 53x292 back-up with striker 16A 80N

Reference 3018013.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 59
Resistance (ohm) 0,169
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 3200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €134.62/pc
Quantity

Fuse 24kV 53x292 back-up with striker 2,5A

Reference 3018013.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 16
Resistance (ohm) 1,92
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 26
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €426.63/pc
Quantity

Fuse 24kV 53x292 back-up with striker 2A 80N

Reference 3018013.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 24000
Applicable standards IEC
Power loss (W) 15
Resistance (ohm) 2,85
Fuse Dimension (mm) 53x292
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 20880
Total clearing I²t @Un AC (A²s) 9,8
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 1640
Price List €101.43/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.