Fuses

Fuse 38,5kV TV DIN 53x537 without striker 2,5A

Reference 3033711.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 27
Resistance (ohm) 3,05
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 22
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 2A

Reference 3033711.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 25
Resistance (ohm) 4,9
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 12
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Price List €117.74/pc
Quantity

Fuse 38,5kV TV DIN 53x537 without striker 3,15A

Reference 3033711.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 2,2
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 4A

Reference 3033711.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 38
Resistance (ohm) 1,64
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV DIN 53x537 without striker 5A

Reference 3033711.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 0,748
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2760
Product available on request Ask for more information

Fuse 38,5kV TV 53x537 with striker 10A 80N

Reference 3033713.10.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 10
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 82
Resistance (ohm) 0,609
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 68
Minimum breaking current (A) 34
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 1300
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2740
Price List €718.21/pc
Quantity

Fuse 38,5kV TV 53x537 with striker 2,5A 80N

Reference 3033713.2,5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2,5
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 27
Resistance (ohm) 3,05
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 7,2
Minimum breaking current (A) 20
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 22
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2759
Product available on request Ask for more information

Fuse 38,5kV TV 53x537 with striker 2A 80N

Reference 3033713.2.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 2
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 25
Resistance (ohm) 4,9
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 3,2
Minimum breaking current (A) 16
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 12
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2759
Price List €118.10/pc
Quantity

Fuse 38,5kV TV 53x537 with striker 3,15A 80N

Reference 3033713.3,15.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 3,15
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 29
Resistance (ohm) 2,2
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 17
Minimum breaking current (A) 24
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 48
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2759
Price List €831.29/pc
Quantity

Fuse 38,5kV TV 53x537 with striker 4A 80N

Reference 3033713.4.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 4
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 38
Resistance (ohm) 1,64
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 31
Minimum breaking current (A) 32
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 90
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2759
Price List €124.77/pc
Quantity

Fuse 38,5kV TV 53x537 with striker 5A 80N

Reference 3033713.5.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 5
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 26
Resistance (ohm) 0,748
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 40
Minimum breaking current (A) 40
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 125
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2759
Price List €832.19/pc
Quantity

Fuse 38,5kV TV 53x537 with striker 6,3A 80N

Reference 3033713.6,3.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 6,3
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 48
Resistance (ohm) 0,957
Fuse Dimension (mm) 53x537
Melting I²t value (A²s) 27
Minimum breaking current (A) 22
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 890
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 2720
Price List €136.56/pc
Quantity

Fuse 38,5kV 67x537 back-up with striker 16A 80N

Reference 3033813.16.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 16
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 108
Resistance (ohm) 0,293
Fuse Dimension (mm) 67x537
Melting I²t value (A²s) 140
Minimum breaking current (A) 56
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 2000
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 4380
Price List €117.90/pc
Quantity

Fuse 38,5kV 67x537 back-up with striker 20A 80N

Reference 3033813.20.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 20
Rated Voltage Un AC (V) 38500
Applicable standards IEC
Power loss (W) 102
Resistance (ohm) 0,148
Fuse Dimension (mm) 67x537
Melting I²t value (A²s) 550
Minimum breaking current (A) 70
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 33495
Total clearing I²t @Un AC (A²s) 7800
Rated breaking capacity I1 AC (kA) 40000
Weight (gr) 4320
Price List €125.93/pc
Quantity

Fuse 12kV 63,5x310 M8-G1/8” oiltight 80A

Reference 3031016.80.0 - Manufacturer SIBA
Class HH Back up
Rated current In (A) 80
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 120
Fuse Dimension (mm) 63,5x310
Melting I²t value (A²s) 17500
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 175000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2780
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 10A

Reference 3031091.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 11
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 2800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 12A

Reference 3031091.12.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 12
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 13
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 340
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 3800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 16A

Reference 3031091.16.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 16
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 17
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 830
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 9200
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €281.28/pc
Quantity

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 20A

Reference 3031091.20.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 20
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 20
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 1730
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 17300
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Product available on request Ask for more information

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 22A

Reference 3031091.22.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 22
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 12
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 2260
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 22600
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €864.45/pc
Quantity

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 40A

Reference 3031091.40.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 40
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 35
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 3530
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 35500
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €305.96/pc
Quantity

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 50A

Reference 3031091.50.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 50
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 46
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 5490
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 55000
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €319.96/pc
Quantity

Fuse 17,5kV 63,5x360 general purpose M8-M8 w/o striker 8A

Reference 3031091.8.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 8
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 8
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 172
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 1800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2600
Price List €250.27/pc
Quantity

Fuse 17,5kV63,5x360general purpose M8-G1/8” +striker10A 50N

Reference 3031096.10.0 - Manufacturer SIBA
Class HH G P
Rated current In (A) 10
Rated Voltage Un AC (V) 12000
Applicable standards IEC
Power loss (W) 11
Fuse Dimension (mm) 63,5x360
Melting I²t value (A²s) 250
Fuse Connection/Terminal type Cylindrical
Voltage of total clearing I2t test 12000
Total clearing I²t @Un AC (A²s) 2800
Rated breaking capacity I1 AC (kA) 63000
Weight (gr) 2540
Price List €926.58/pc
Quantity
Filter by
Manufacturer
Series name
Fuse size
Class
Fuse Connection/Terminal type
Rated current In (A)
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Applicable standards
Product added to compare.
Product added to wishlist