Fuses

Fuse 750V NH3L / SQB2 aSt 250A

Reference 2003166.250.0 - Manufacturer SIBA
Class aSt
Rated current In (A) 250
Rated Voltage Un AC (V) 750
Rated break.capacity I1 AC (A) 30000
Format NH knife contact
Pre-arcing I2t value (A2s) 26500
Total I2t value (A2s) 188000
Power loss (W) 51
Time costant L/R (ms) 10
Product available on request Ask for more information

Fuse 750V NH3L / SQB2 aSt 315A

Reference 2003166.315.0 - Manufacturer SIBA
Class aSt
Rated current In (A) 315
Rated Voltage Un AC (V) 750
Rated break.capacity I1 AC (A) 30000
Format NH knife contact
Pre-arcing I2t value (A2s) 47200
Total I2t value (A2s) 335000
Power loss (W) 61
Time costant L/R (ms) 10
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 125A

Reference 2003435.125.0 - Manufacturer SIBA
Class gR
Rated current In (A) 125
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 21000
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 5400
Total I2t value (A2s) 30000
Power loss (W) 22
Rated Voltage Un DC (V) 900
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 160A

Reference 2003435.160.0 - Manufacturer SIBA
Class gR
Rated current In (A) 160
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 9500
Total I2t value (A2s) 52000
Power loss (W) 27
Rated Voltage Un DC (V) 900
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 200A

Reference 2003435.200.0 - Manufacturer SIBA
Class gR
Rated current In (A) 200
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 21500
Total I2t value (A2s) 116000
Power loss (W) 30
Rated Voltage Un DC (V) 900
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 250A

Reference 2003435.250.0 - Manufacturer SIBA
Class gR
Rated current In (A) 250
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 38200
Total I2t value (A2s) 206000
Power loss (W) 34
Rated Voltage Un DC (V) 900
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 315A

Reference 2003435.315.0 - Manufacturer SIBA
Class gR
Rated current In (A) 315
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 57100
Total I2t value (A2s) 307000
Power loss (W) 50
Rated Voltage Un DC (V) 900
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 900V NH3L / SQB-DC93 gR 350A

Reference 2003435.350.0 - Manufacturer SIBA
Class gR
Rated current In (A) 350
Rated Voltage Un AC (V) 900
Rated break.capacity I1 AC (A) 100000
Format NH knife contact
Pre-arcing I2t value (A2s) 79700
Total I2t value (A2s) 428000
Power loss (W) 52
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 800V NH3L / SQB-DC93 gR 400A

Reference 2003435.400.0 - Manufacturer SIBA
Class gR
Rated current In (A) 400
Rated Voltage Un AC (V) 800
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 106000
Total I2t value (A2s) 561000
Power loss (W) 58
Rated Voltage Un DC (V) 800
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 800V NH3L / SQB-DC93 gR 450A

Reference 2003435.450.0 - Manufacturer SIBA
Class gR
Rated current In (A) 450
Rated Voltage Un AC (V) 800
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 153000
Total I2t value (A2s) 790000
Power loss (W) 62
Rated Voltage Un DC (V) 800
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Price List €246.27/pc
Quantity

Fuse 800V NH3L / SQB-DC93 gR 500A

Reference 2003435.500.0 - Manufacturer SIBA
Class gR
Rated current In (A) 500
Rated Voltage Un AC (V) 800
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 189000
Total I2t value (A2s) 975000
Power loss (W) 74
Rated Voltage Un DC (V) 800
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information

Fuse 800V NH3L / SQB-DC93 gR 550A

Reference 2003435.550.0 - Manufacturer SIBA
Class gR
Rated current In (A) 550
Rated Voltage Un AC (V) 800
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 900
Weight (g) 2100
Format Screw fixing
Dimension SQB-DC93
Pre-arcing I2t value (A2s) 258000
Total I2t value (A2s) 1330000
Power loss (W) 79
Rated Voltage Un DC (V) 800
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 8
Product available on request Ask for more information
Filter by
Manufacturer
Class
Series name
more... less
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated current In (A)
Format
Dimension
Homologations
Pre-arcing I2t value (A2s)
Total I2t value (A2s)
Product added to compare.
Product added to wishlist