800GNH1 - Fuse NH1 800V gG 125A

Reference R61.840.76.0.0 - Manufacturer TechnoTeam
Class gG
Rated current In (A) 125
Rated Voltage Un AC (V) 800
Rated break.capacity I1 AC (A) 80000
Voltage of total I2t test 800
Format NH knife contact
Dimension NH1
Pre-arcing I2t value (A2s) 28000
Total I2t value (A2s) 275000
Homologations IEC
Power loss (W) 13
Price List €60.03/pc
Quantity

C100 - Fuse 690V aR size 1 M8 550A

Reference 114.997.24.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 550
Rated Voltage Un AC (V) 690
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 690
Format Screw fixing
Dimension SQB2
Pre-arcing I2t value (A2s) 33000
Total I2t value (A2s) 230000
Homologations IEC
Power loss (W) 84
Series name C100
Product available on request Ask for more information

C100 - Fuse 690V aR size 1 M8 160A

Reference 115.115.26.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 160
Rated Voltage Un AC (V) 690
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 690
Format Screw fixing
Dimension SQB2
Pre-arcing I2t value (A2s) 1100
Total I2t value (A2s) 7500
Homologations IEC
Power loss (W) 24
Series name C100
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 2A

Reference 161.846.26.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 2
Rated Voltage Un AC (V) 500
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 500
Format Cylindrical
Pre-arcing I2t value (A2s) 2,7
Total I2t value (A2s) 17,5
Homologations IEC
Power loss (W) o,6
Fuses dimension 10x38
Series name G103
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 1A

Reference 167.818.84.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 1
Rated Voltage Un AC (V) 500
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 500
Format Cylindrical
Pre-arcing I2t value (A2s) 2,4
Total I2t value (A2s) 15,5
Homologations IEC
Power loss (W) 1,9
Fuses dimension 10x38
Series name G103
Product available on request Ask for more information

C100 - Fuse 690V aR size 1 M8 50A

Reference 171.033.15.0.0 - Manufacturer FAULTRAP
Class aR
Rated current In (A) 50
Rated Voltage Un AC (V) 690
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 690
Format Screw fixing
Dimension SQB2
Pre-arcing I2t value (A2s) 77
Total I2t value (A2s) 510
Homologations IEC
Power loss (W) 8
Series name C100
Product available on request Ask for more information

G276 - Fuse 500V AC gG /550V gR 27x60 PCB 100A

Reference 171.902.24.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 100
Rated Voltage Un AC (V) 500
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 500
Format Cylindrical
Pre-arcing I2t value (A2s) 23650
Total I2t value (A2s) 84000
Homologations IEC
Power loss (W) 8
Fuses dimension 27x60
Series name G276
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 20A

Reference 178.800.45.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 20
Rated Voltage Un AC (V) 500
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 500
Format Cylindrical
Pre-arcing I2t value (A2s) 33,5
Total I2t value (A2s) 242
Homologations IEC
Power loss (W) 1,9
Fuses dimension 10x38
Series name G103
Product available on request Ask for more information

G103 - Fuse 500V 10x38 gG 12A

Reference 181.299.73.0.0 - Manufacturer FAULTRAP
Class gG
Rated current In (A) 12
Rated Voltage Un AC (V) 500
Rated break.capacity I1 AC (A) 100000
Voltage of total I2t test 500
Format Cylindrical
Pre-arcing I2t value (A2s) 13
Total I2t value (A2s) 106
Homologations IEC
Power loss (W) 1,2
Fuses dimension 10x38
Series name G103
Product available on request Ask for more information

Fuse NH3L gPV 1100VDC 300A

Reference 2003129.300.0 - Manufacturer SIBA
Class gPV
Rated current In (A) 300
Voltage of total I2t test 1100
Format NH knife contact
Dimension NH3L
Pre-arcing I2t value (A2s) 38000
Total I2t value (A2s) 1850000
Power loss (W) 62
Rated Voltage Un DC (V) 1100
Rated break.capacity I1 DC (A) 30000
Price List €139.49/pc
Quantity

Fuse NH1XL 1500V DC gBat without ind. 100A

Reference 2004136.100.0 - Manufacturer SIBA
Rated current In (A) 100
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1650
Total I2t value (A2s) 9900
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 125A

Reference 2004136.125.0 - Manufacturer SIBA
Rated current In (A) 125
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 2950
Total I2t value (A2s) 18000
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 160A

Reference 2004136.160.0 - Manufacturer SIBA
Rated current In (A) 160
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 5600
Total I2t value (A2s) 34000
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 200A

Reference 2004136.200.0 - Manufacturer SIBA
Rated current In (A) 200
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 14300
Total I2t value (A2s) 85000
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 50A

Reference 2004136.50.0 - Manufacturer SIBA
Rated current In (A) 50
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 361
Total I2t value (A2s) 2200
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 63A

Reference 2004136.63.0 - Manufacturer SIBA
Rated current In (A) 63
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 480
Total I2t value (A2s) 2900
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat without ind. 80A

Reference 2004136.80.0 - Manufacturer SIBA
Rated current In (A) 80
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1060
Total I2t value (A2s) 6400
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind.100A

Reference 2004137.100.0 - Manufacturer SIBA
Rated current In (A) 100
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1650
Total I2t value (A2s) 9900
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 125A

Reference 2004137.125.0 - Manufacturer SIBA
Rated current In (A) 125
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 2950
Total I2t value (A2s) 18000
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 160A

Reference 2004137.160.0 - Manufacturer SIBA
Rated current In (A) 160
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 5600
Total I2t value (A2s) 34000
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 200A

Reference 2004137.200.0 - Manufacturer SIBA
Rated current In (A) 200
Voltage of total I2t test 85000
Format NH knife contact
Dimension NH1XL
Total I2t value (A2s) 14300
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 50A

Reference 2004137.50.0 - Manufacturer SIBA
Rated current In (A) 50
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 361
Total I2t value (A2s) 2200
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 63A

Reference 2004137.63.0 - Manufacturer SIBA
Rated current In (A) 63
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 480
Total I2t value (A2s) 2900
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat with ind. 80A

Reference 2004137.80.0 - Manufacturer SIBA
Rated current In (A) 80
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1060
Total I2t value (A2s) 6400
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 100A

Reference 2004536.100.0 - Manufacturer SIBA
Rated current In (A) 100
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1650
Total I2t value (A2s) 9900
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 125A

Reference 2004536.125.0 - Manufacturer SIBA
Rated current In (A) 125
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 2950
Total I2t value (A2s) 18000
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind.160A

Reference 2004536.160.0 - Manufacturer SIBA
Rated current In (A) 160
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 5600
Total I2t value (A2s) 34000
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 200A

Reference 2004536.200.0 - Manufacturer SIBA
Rated current In (A) 200
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 14300
Total I2t value (A2s) 85000
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 50A

Reference 2004536.50.0 - Manufacturer SIBA
Rated current In (A) 50
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 361
Total I2t value (A2s) 2200
Power loss (W) 18
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 63A

Reference 2004536.63.0 - Manufacturer SIBA
Rated current In (A) 63
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 480
Total I2t value (A2s) 2900
Power loss (W) 22
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US blade without ind. 80A

Reference 2004536.80.0 - Manufacturer SIBA
Rated current In (A) 80
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1060
Total I2t value (A2s) 6400
Power loss (W) 24
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 100A

Reference 2004537.100.0 - Manufacturer SIBA
Rated current In (A) 100
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 1650
Total I2t value (A2s) 9900
Power loss (W) 25
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 125A

Reference 2004537.125.0 - Manufacturer SIBA
Rated current In (A) 125
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 2950
Total I2t value (A2s) 18000
Power loss (W) 27
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 160A

Reference 2004537.160.0 - Manufacturer SIBA
Rated current In (A) 160
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 5600
Total I2t value (A2s) 34000
Power loss (W) 37
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information

Fuse NH1XL 1500V DC gBat US with ind. 200A

Reference 2004537.200.0 - Manufacturer SIBA
Rated current In (A) 200
Voltage of total I2t test 1500
Format NH knife contact
Dimension NH1XL
Pre-arcing I2t value (A2s) 14300
Total I2t value (A2s) 85000
Power loss (W) 44
Rated Voltage Un DC (V) 1500
Rated break.capacity I1 DC (A) 100000
Time costant L/R (ms) 3
Product available on request Ask for more information
Filter by
Manufacturer
Class
Series name
more... less
Rated Voltage Un AC (V)
Rated Voltage Un DC (V)
Rated current In (A)
Format
Dimension
Homologations
Pre-arcing I2t value (A2s)
Total I2t value (A2s)
Product added to compare.
Product added to wishlist