500V

There are 75 products.
Showing 1 - 24 of 75 items
  • Fuse NH2 500V Ty with top indicator 160A
    2000412.160.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 62000
    • Total I2t value (A2s) 280000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Power loss (W) 16
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 610
  • Fuse NH2 500V Ty with top indicator and insulated cover 100A
    2044212.100.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 21000
    • Total I2t value (A2s) 91000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Rated break.capacity I1 DC (A) 100000
    • Power loss (W) 11
    • Format Knife contacts
    • Dimension NH2
  • Fuse NH2 500V gB flameproof 200A
    2000403.200.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 16000
    • Total I2t value (A2s) 64000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 25
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 620
  • Fuse NH0 gB 500V flameproof 25A
    2000203.25.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 250
    • Total I2t value (A2s) 1000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 4,5
    • Format Knife contacts
    • Dimension NH0
    • Weight (g) 250
  • Fuse NH1 500V gB flameproof 20A
    2000303.20.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 140
    • Total I2t value (A2s) 570
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 3,8
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 390
  • Fuse gB NH00 500V flameproof 50A
    2000103.50.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 50
    • Pre-arcing I2t value (A2s) 580
    • Total I2t value (A2s) 2300
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 5,3
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 170
  • Fuse NH3 500V gB flameproof 425A
    2000503.425.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 425
    • Pre-arcing I2t value (A2s) 98000
    • Total I2t value (A2s) 393000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 48
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 880
  • Fuse NH4 gTF 500V 1000A
    2003202.1000.0
    Manufacturer: SIBA

     
    • Class gTF
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 1000
    • Pre-arcing I2t value (A2s) 5800000
    • Total I2t value (A2s) 14400000
    • Voltage of total I2t test 440
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 78
    • Format Screw fixing
    • Dimension NH4
    • Weight (g) 2300
  • Fuse NH2 500V Ty with top indicator 315A
    2000412.315.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 315
    • Pre-arcing I2t value (A2s) 380000
    • Total I2t value (A2s) 1800000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Power loss (W) 27
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 610
  • Fuse NH2 500V Ty with top indicator and insulated cover 200A
    2044212.200.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 140000
    • Total I2t value (A2s) 560000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Rated break.capacity I1 DC (A) 100000
    • Power loss (W) 19
    • Format Knife contacts
    • Dimension NH2
  • Fuse NH2 500V gB flameproof 315A
    2000403.315.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 315
    • Pre-arcing I2t value (A2s) 46000
    • Total I2t value (A2s) 181000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 36
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 620
  • Fuse NH0 gB 500V flameproof 10A
    2000203.10.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 32
    • Total I2t value (A2s) 130
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 2,2
    • Format Knife contacts
    • Dimension NH0
    • Weight (g) 250
  • Fuse NH1 500V gB flameproof 25A
    2000303.25.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 250
    • Total I2t value (A2s) 1000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 4,5
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 390
  • Fuse gB NH00 500V flameproof 80A
    2000103.80.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 6800
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 8,2
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 160
  • Fuse NH3 500V gB flameproof 630A
    2000503.630.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 630
    • Pre-arcing I2t value (A2s) 208000
    • Total I2t value (A2s) 830000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 68
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 800
  • Fuse NH2 500V Ty with top indicator 355A
    2000412.355.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 355
    • Pre-arcing I2t value (A2s) 490000
    • Total I2t value (A2s) 2200000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Power loss (W) 32
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 610
  • Fuse NH2 500V Ty with top indicator and insulated cover 224A
    2044212.224.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 224
    • Pre-arcing I2t value (A2s) 180000
    • Total I2t value (A2s) 790000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Rated break.capacity I1 DC (A) 100000
    • Power loss (W) 21
    • Format Knife contacts
    • Dimension NH2
  • Fuse NH2 500V gB flameproof 80A
    2000403.80.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 6800
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 12
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 600
  • Fuse NH0 gB 500V flameproof 35A
    2000203.35.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 35
    • Pre-arcing I2t value (A2s) 290
    • Total I2t value (A2s) 1100
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 6
    • Format Knife contacts
    • Dimension NH0
    • Weight (g) 240
  • Fuse NH1 500V gB flameproof 100A
    2000303.100.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 3300
    • Total I2t value (A2s) 13000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 14
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 390
  • Fuse gB NH00 500V flameproof 10A
    2000103.10.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 32
    • Total I2t value (A2s) 130
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 1,6
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 170
  • Fuse NH3 500V gB flameproof 400A
    2000503.400.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 400
    • Pre-arcing I2t value (A2s) 92000
    • Total I2t value (A2s) 369000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 120000
    • Power loss (W) 45
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 880
  • Fuse NH2 500V Ty with top indicator 100A
    2000412.100.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 100
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 610
  • Fuse NH2 500V Ty with top indicator and insulated cover 63A
    2044212.63.0
    Manufacturer: SIBA

     
    • Class Ty
    • Rated Voltage Un AC (V) 500
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 7100
    • Total I2t value (A2s) 31000
    • Voltage of total I2t test 500
    • Rated break.capacity I1 AC (A) 100000
    • Rated break.capacity I1 DC (A) 100000
    • Power loss (W) 7,6
    • Format Knife contacts
    • Dimension NH2
Accept