gB

There are 69 products.
Showing 1 - 24 of 69 items
  • Fuse NH00C long gB 1000V 10A
    2038603.10.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 31
    • Total I2t value (A2s) 93
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 1,5
    • Format Knife contacts
    • Dimension NH00C
    • Weight (g) 170
  • Fuse NH00 long gB 1000V 100A
    2038903.100.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 3300
    • Total I2t value (A2s) 9900
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 18,3
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 280
  • Fuse NH2 gB AC 1000V 125A
    2039603.125.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 6800
    • Total I2t value (A2s) 27000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 21
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 760
  • Fuse NH3 gB AC 1000V 250A
    2039703.250.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 250
    • Pre-arcing I2t value (A2s) 41000
    • Total I2t value (A2s) 164000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 32
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 1030
  • Fuse NH3C gB AC 1000V with switch adapter 16A
    2035803.16.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 52
    • Total I2t value (A2s) 210
    • Voltage of total I2t test 1000
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 3,2
    • Format Knife contacts
    • Dimension NH3C
    • Weight (g) 1160
  • Fuse NH1 gB AC 1000V 35A
    2039903.35.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 35
    • Pre-arcing I2t value (A2s) 440
    • Total I2t value (A2s) 1760
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 7,5
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 560
  • Fuse NH00C long gB 1000V 35A
    2038603.35.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 35
    • Pre-arcing I2t value (A2s) 440
    • Total I2t value (A2s) 1320
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 6,6
    • Format Knife contacts
    • Dimension NH00C
    • Weight (g) 170
  • Fuse NH00 long gB 1000V 63A
    2038903.63.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 1350
    • Total I2t value (A2s) 4050
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 11
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 270
  • Fuse NH2 gB AC 1000V 80A
    2039603.80.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 6800
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 14
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 860
  • Fuse NH3 gB AC 1000V 25A
    2039703.25.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 210
    • Total I2t value (A2s) 840
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 3,6
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 1140
  • Fuse NH3C gB AC 1000V with switch adapter 160A
    2035803.160.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 9030
    • Total I2t value (A2s) 36200
    • Voltage of total I2t test 1000
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 20
    • Format Knife contacts
    • Dimension NH3C
    • Weight (g) 1160
  • Fuse NH1 gB AC 1000V 25A
    2039903.25.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 210
    • Total I2t value (A2s) 840
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 5,7
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 560
  • Fuse NH00C long gB 1000V 40A
    2038603.40.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 40
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Format Knife contacts
    • Dimension NH00C
    • Weight (g) 170
  • Fuse NH00 long gB 1000V 50A
    2038903.50.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 50
    • Pre-arcing I2t value (A2s) 870
    • Total I2t value (A2s) 2610
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 8,8
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 270
  • Fuse NH2 gB AC 1000V 200A
    2039603.200.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 27000
    • Total I2t value (A2s) 108000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 30
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 880
  • Fuse NH3 gB AC 1000V 80A
    2039703.80.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 6800
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 11
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 1030
  • Fuse NH3C gB AC 1000V with switch adapter 6A
    2035803.6.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 6
    • Pre-arcing I2t value (A2s) 6,4
    • Total I2t value (A2s) 26
    • Voltage of total I2t test 1000
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 1,4
    • Format Knife contacts
    • Dimension NH3C
    • Weight (g) 950
  • Fuse NH1 gB AC 1000V 160A
    2039903.160.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 16000
    • Total I2t value (A2s) 64000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 26
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 560
  • Fuse NH00C long gB 1000V 63A
    2038603.63.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 1350
    • Total I2t value (A2s) 4050
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 11
    • Format Knife contacts
    • Dimension NH00C
    • Weight (g) 213
  • Fuse NH00 long gB 1000V 125A
    2038903.125.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 4700
    • Total I2t value (A2s) 14100
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 22,5
    • Format Knife contacts
    • Dimension NH00
    • Weight (g) 280
  • Fuse NH2 gB AC 1000V 160A
    2039603.160.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 16000
    • Total I2t value (A2s) 64000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 25
    • Format Knife contacts
    • Dimension NH2
    • Weight (g) 760
  • Fuse NH3 gB AC 1000V 63A
    2039703.63.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 1000
    • Total I2t value (A2s) 4000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 8,6
    • Format Knife contacts
    • Dimension NH3
    • Weight (g) 1140
  • Fuse NH3C gB AC 1000V with switch adapter 63A
    2035803.63.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 1152
    • Total I2t value (A2s) 4610
    • Voltage of total I2t test 1000
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 11
    • Format Knife contacts
    • Dimension NH3C
    • Weight (g) 950
  • Fuse NH1 gB AC 1000V 100A
    2039903.100.0
    Manufacturer: SIBA

     
    • Class gB
    • Rated Voltage Un AC (V) 1000
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 4000
    • Total I2t value (A2s) 16000
    • Voltage of total I2t test 760
    • Rated break.capacity I1 AC (A) 25000
    • Power loss (W) 18
    • Format Knife contacts
    • Dimension NH1
    • Weight (g) 560
Accept