1100VDC

There are 10 products.
Showing 1 - 10 of 10 items
  • Fuse NH1XL gRL 1100V DC 80A
    2002834.80.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 8900
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 18
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 200A
    2002834.200.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 19200
    • Total I2t value (A2s) 126000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 38
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 75A
    2002834.75.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 75
    • Pre-arcing I2t value (A2s) 1400
    • Total I2t value (A2s) 4700
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 17
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 100A
    2002834.100.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 3600
    • Total I2t value (A2s) 19000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 19
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 150A
    2002834.150.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 150
    • Pre-arcing I2t value (A2s) 11200
    • Total I2t value (A2s) 59000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 27
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 175A
    2002834.175.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 175
    • Pre-arcing I2t value (A2s) 14900
    • Total I2t value (A2s) 98000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 35
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 125A
    2002834.125.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 6700
    • Total I2t value (A2s) 35000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 21
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 50A
    2002834.50.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 50
    • Pre-arcing I2t value (A2s) 360
    • Total I2t value (A2s) 1900
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 14
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 160A
    2002834.160.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 11200
    • Total I2t value (A2s) 59000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 30
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH1XL gRL 1100V DC 63A
    2002834.63.0
    Manufacturer: SIBA

     
    • Class gRL/gS-gR
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 900
    • Total I2t value (A2s) 4700
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 AC (A) 50000
    • Time costant L/R (ms) 10
    • Power loss (W) 15
    • Homologations IEC-UL
    • Weight (g) 770
Accept

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies. More information