  • Fuse 15kV 359x63,5 screw M16 for capacitors 25A
    3036121.25.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 1050
    • Total I2t value (A2s) 6700
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 56
    • Format Cylindrical
    • Dimension 359x63,5mm
    • Homologations IEC
    • Weight (g) 2600
  • Fuse 15,5kV 63,5x254 screw M12 capacitor protection 40A
    3041726.40.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 40
    • Pre-arcing I2t value (A2s) 2900
    • Total I2t value (A2s) 17100
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 84
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2111
  • Fuse 23kV 63,5x359 screw M12 capacitor protection 25A
    3041926.25.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 23000
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 1050
    • Total I2t value (A2s) 6700
    • Voltage of total I2t test 23000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 84
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
  • Fuse 8,3kV 63,5x359 screw M12 capacitor protection 100A
    3051226.100.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 8300
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 33000
    • Total I2t value (A2s) 189000
    • Voltage of total I2t test 8300
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 95
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
  • Fuse 4,8 kV 76x254 M16 160A
    3035721.160.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 4800
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 90000
    • Total I2t value (A2s) 513000
    • Voltage of total I2t test 4800
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 93
    • Format Cylindrical
    • Dimension 4,8 kV
    • Homologations IEC
    • Weight (g) 2060
  • Fuse 15kV 359x63,5 screw M16 for capacitors 20A
    3036121.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 640
    • Total I2t value (A2s) 4300
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 40
    • Format Cylindrical
    • Dimension 359x63,5mm
    • Homologations IEC
    • Weight (g) 2600
  • Fuse 4,8 kV 76x254 M16 125A
    3035721.125.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 4800
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 47000
    • Total I2t value (A2s) 351000
    • Voltage of total I2t test 4800
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 78
    • Format Cylindrical
    • Dimension 4,8 kV
    • Homologations IEC
    • Weight (g) 2060
  • Fuse 7,2kV 254x63,5 screw M16 for capacitors 63A
    3035921.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 10700
    • Total I2t value (A2s) 59400
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 55
    • Format Cylindrical
    • Dimension 254x63,5mm
    • Homologations IEC
    • Weight (g) 2040
  • Fuse 23kV 63,5x359 screw 1/2 UNC capacitor protection 6,3A
    3039026.6,3.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 6,3
    • Pre-arcing I2t value (A2s) 45
    • Total I2t value (A2s) 330
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 31
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2880
  • Fuse 7,2 kV 63,5x254 1/2 UNC 10A
    3035221.10.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 75
    • Total I2t value (A2s) 500
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 22
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2040
  • Fuse 15,5kV 290x63,5 screw M16 capacitor protection 16A
    3040726.16.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 250
    • Total I2t value (A2s) 1800
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 37
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2080
  • Fuse 5,5kV 63,5x254 capacitor protection 20A
    3041026.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 5500
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 640
    • Total I2t value (A2s) 4300
    • Voltage of total I2t test 5500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 15
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2160
  • Fuse 4,8 kV 63,5x254 1/2 UNC 31,5A
    3034921.31,5.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 4800
    • Rated current In (A) 31,5
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 10800
    • Voltage of total I2t test 4800
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 20
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2000
  • Fuse 8,3kV capacitor protection 290x63,5 16A
    3038726.16.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 8300
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 250
    • Total I2t value (A2s) 1800
    • Voltage of total I2t test 8300
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 22
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2100
  • Fuse 7,2 kV 76x359 1/2 UNC 125A
    3035321.125.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 7200
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 47000
    • Total I2t value (A2s) 351000
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 117
    • Format Cylindrical
    • Dimension 76x359mm
    • Homologations IEC
    • Weight (g) 3820
  • Fuse 4,8 kV 63,5x254 1/2 UNC 20A
    3034921.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 4800
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 640
    • Total I2t value (A2s) 4300
    • Voltage of total I2t test 4800
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 14
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1900
  • Fuse 4,8 kV 63,5x254 1/2 UNC 80A
    3034921.80.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 4800
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 21000
    • Total I2t value (A2s) 126000
    • Voltage of total I2t test 4800
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 42
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2052
  • Fuse 8,3kV 63,5x359 screw M12 capacitor protection 63A
    3051226.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 8300
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 10700
    • Total I2t value (A2s) 59400
    • Voltage of total I2t test 8300
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 64
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
  • Fuse 15,5kV 63,5x359 1/2 UNC 80A
    3035421.80.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 21000
    • Total I2t value (A2s) 126000
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 137
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2800
  • Fuse 5,5kV capacitor protection 290x63,5 25A
    3038426.25.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 5500
    • Rated current In (A) 25
    • Pre-arcing I2t value (A2s) 1050
    • Total I2t value (A2s) 6700
    • Voltage of total I2t test 5500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 17
    • Dimension 63,5x254mm
    • Weight (g) 2135
  • Fuse 23kV 395x63,5 screw M16 capacitor protection 10A
    3040926.10.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 23000
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 75
    • Total I2t value (A2s) 500
    • Voltage of total I2t test 23000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 57
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2940
  • Fuse 23kV 63,5x359 capacitor protection 40A
    3041626.40.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 40
    • Pre-arcing I2t value (A2s) 2900
    • Total I2t value (A2s) 17100
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 125
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2900
  • Fuse 15,5kV 63,5x254 screw M12 capacitor protection 16A
    3041726.16.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 250
    • Total I2t value (A2s) 1800
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 37
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 2111
  • Fuse 8,3kV 63,5x359 capacitor protection 80A
    3041226.80.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 8300
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 21000
    • Total I2t value (A2s) 126000
    • Voltage of total I2t test 8300
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 73
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2680