Back up

There are 162 products.
Showing 1 - 24 of 162 items
  • Fuse 12kV 63,5x254 F01 oiltight 6,3A
    3014436.6,3.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 6,3
    • Pre-arcing I2t value (A2s) 14
    • Total I2t value (A2s) 140
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1840
  • Fuse 12kV 63,5x359 F02 oiltight 20A
    3023736.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 290
    • Total I2t value (A2s) 2900
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2440
  • Fuse 15,5kV 63,5x254 F01 oiltight 20A
    3029336.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 290
    • Total I2t value (A2s) 2900
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1790
  • Fuse 12kV 63,5x310 M8-M8 oiltight 31,5A
    3031011.31,5.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 31,5
    • Pre-arcing I2t value (A2s) 1700
    • Total I2t value (A2s) 12000
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 38
    • Format Cylindrical
    • Dimension 63,5x310mm
    • Homologations IEC
    • Weight (g) 2540
  • Fuse 24kV 63,5x360 M8 oiltight with striker 16A
    3031215.16.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 24000
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 120
    • Total I2t value (A2s) 1200
    • Voltage of total I2t test 24000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 61
    • Format Cylindrical
    • Dimension 63,5x360mm
    • Homologations IEC
    • Weight (g) 2529
  • Fuse 7,2kV 63,5x254 F01 oiltight 16A
    3013236.16.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 7200
    • Rated current In (A) 16
    • Pre-arcing I2t value (A2s) 190
    • Total I2t value (A2s) 1800
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1780
  • Fuse 7,2kV 63,5x254 F01 oiltight 20A
    3013236.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 7200
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 290
    • Total I2t value (A2s) 2900
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1780
  • Fuse 12kV 63,5x310 M8-M8 oiltight 63A
    3031011.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 10700
    • Total I2t value (A2s) 66000
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 63
    • Format Cylindrical
    • Dimension 63,5x310mm
    • Homologations IEC
    • Weight (g) 2540
  • Fuse 7,2kV 63,5x254 F01 oiltight 80A
    3013236.80.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 7200
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 9900
    • Total I2t value (A2s) 100000
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1780
  • Fuse 15,5kV 63,5x254 F01 oiltight 50A
    3029336.50.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 50
    • Pre-arcing I2t value (A2s) 2800
    • Total I2t value (A2s) 36000
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1790
  • Fuse 36kV 63,5x360 M8/M8 oiltight 6,3A
    3032311.6,3.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 36000
    • Rated current In (A) 6,3
    • Pre-arcing I2t value (A2s) 45
    • Total I2t value (A2s) 360
    • Voltage of total I2t test 36000
    • Rated break.capacity I1 AC (A) 40000
    • Power loss (W) 49
    • Format Cylindrical
    • Dimension 63,5x360mm
    • Homologations IEC
    • Weight (g) 2580
  • Fuse 7,2kV 63,5x254 F01 oiltight 100A
    3013236.100.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 7200
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 22200
    • Total I2t value (A2s) 218500
    • Voltage of total I2t test 7200
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1780
  • Fuse 24kV 63,5x359 F02 oiltight 40A
    3015636.40.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 24000
    • Rated current In (A) 40
    • Pre-arcing I2t value (A2s) 2300
    • Total I2t value (A2s) 22300
    • Voltage of total I2t test 24000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2450
  • Fuse 12kV 63,5x359 F02 oiltight 100A
    3023736.100.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 100
    • Pre-arcing I2t value (A2s) 22200
    • Total I2t value (A2s) 218500
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2440
  • Fuse 15,5kV 63,5x254 F01 oiltight 63A
    3029336.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 6500
    • Total I2t value (A2s) 65500
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1790
  • Fuse 12kV 63,5x310 M8-M8 oiltight 10A
    3031011.10.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 75
    • Total I2t value (A2s) 560
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 28
    • Format Cylindrical
    • Dimension 63,5x310mm
    • Homologations IEC
    • Weight (g) 2540
  • Fuse 36kV 63,5x360 M8/G1/8 oiltight with striker 6,3A
    3032316.6,3.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 36000
    • Rated current In (A) 6,3
    • Pre-arcing I2t value (A2s) 45
    • Total I2t value (A2s) 360
    • Voltage of total I2t test 36000
    • Rated break.capacity I1 AC (A) 40000
    • Power loss (W) 49
    • Format Cylindrical
    • Dimension 63,5x360mm
    • Homologations IEC
  • Fuse 12kV 63,5x254 F01 oiltight 90A
    3014436.90.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 90
    • Pre-arcing I2t value (A2s) 15500
    • Total I2t value (A2s) 157000
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1860
  • Fuse 24kV 63,5x359 F02 oiltight 63A
    3015636.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 24000
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 6500
    • Total I2t value (A2s) 65500
    • Voltage of total I2t test 24000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 2450
  • Fuse 15,5kV 63,5x359 F02 oiltight 63A
    3029436.63.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 15500
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 6500
    • Total I2t value (A2s) 65500
    • Voltage of total I2t test 15500
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x359mm
    • Homologations IEC
    • Weight (g) 1500
  • Fuse 12kV 63,5x310 M8-G1/8” oiltight 6,3A
    3031016.6,3.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 6,3
    • Pre-arcing I2t value (A2s) 45
    • Total I2t value (A2s) 360
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 63000
    • Power loss (W) 16
    • Format Cylindrical
    • Dimension 63,5x310mm
    • Homologations IEC
    • Weight (g) 2780
  • Fuse 36kV 63,5x360 M8/M8 oiltight 4A
    3032311.4.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 36000
    • Rated current In (A) 4
    • Pre-arcing I2t value (A2s) 29
    • Total I2t value (A2s) 190
    • Voltage of total I2t test 36000
    • Rated break.capacity I1 AC (A) 40000
    • Power loss (W) 33
    • Format Cylindrical
    • Dimension 63,5x360mm
    • Homologations IEC
    • Weight (g) 2677
  • Fuse 24kV 53x442 back-up oil applications with striker 20A
    3033013.20.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 24000
    • Rated current In (A) 20
    • Pre-arcing I2t value (A2s) 540
    • Total I2t value (A2s) 4100
    • Voltage of total I2t test 2400
    • Rated break.capacity I1 AC (A) 63000
    • Rated break.capacity I1 DC (A) 63000
    • Power loss (W) 46
    • Format Cylindrical
    • Dimension 53x442mm
    • Homologations IEC
    • Weight (g) 2260
  • Fuse 12kV 63,5x254 F01 oiltight 10A
    3014436.10.0
    Manufacturer: SIBA

     
    • Class HH Back up
    • Rated Voltage Un AC (V) 12000
    • Rated current In (A) 10
    • Pre-arcing I2t value (A2s) 50
    • Total I2t value (A2s) 450
    • Voltage of total I2t test 12000
    • Rated break.capacity I1 AC (A) 40000
    • Format Cylindrical
    • Dimension 63,5x254mm
    • Homologations IEC
    • Weight (g) 1960
Accept