1100VDC

There are 69 products.
Showing 1 - 24 of 69 items
  • Fuse SQB2 gPV UL 2579 1100VDC 300A
    2003429.300.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 300
    • Pre-arcing I2t value (A2s) 38000
    • Total I2t value (A2s) 185000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 56
    • Format Screw fixing
    • Dimension 2 US
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse SQB2 US style gPV UL 2579 1100VDC 450A
    2003429.450.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 450
    • Pre-arcing I2t value (A2s) 92500
    • Total I2t value (A2s) 450000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 87
    • Format Screw fixing
    • Dimension 2 US
    • Weight (g) 1380
  • Fuse SQB1 screw M8 gPV 1100VDC 175A
    2001928.175.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 175
    • Pre-arcing I2t value (A2s) 9600
    • Total I2t value (A2s) 31500
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 3
    • Power loss (W) 37
    • Format Screw fixing
    • Dimension 1 screw M8
    • Homologations IEC
  • Fuse NH1XL gPV UL 2579 1100V DC 175A
    2002829.175.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 175
    • Pre-arcing I2t value (A2s) 9600
    • Total I2t value (A2s) 31500
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 37
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC
    • Weight (g) 780
  • Fuse NH1XL gPV 1100V DC 125A
    2002820.125.0
    Manufacturer: SIBA

    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 125
    • Pre-arcing I2t value (A2s) 6700
    • Total I2t value (A2s) 28000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 10
    • Power loss (W) 21
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC-UL
    • Weight (g) 800
  • Fuse NH1XL gPV UL 2579 1100V DC 80A
    2002829.80.0
    Manufacturer: SIBA

    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1100
    • Total I2t value (A2s) 4000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 23
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC
    • Weight (g) 760
  • Fuse SQB2 screw fixing gPV UL 2579 1100VDC 450A
    2003428.450.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 450
    • Pre-arcing I2t value (A2s) 92500
    • Total I2t value (A2s) 450000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 87
    • Format Screw fixing
    • Dimension 2 US
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse SQB1 screw M8 gPV 1100VDC 160A
    2001928.160.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 7600
    • Total I2t value (A2s) 25000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 3
    • Power loss (W) 36
    • Format Screw fixing
    • Dimension 1 screw M8
    • Homologations IEC
  • Fuse NH1XL gPV 1100V DC 63A
    2002820.63.0
    Manufacturer: SIBA

    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 63
    • Pre-arcing I2t value (A2s) 900
    • Total I2t value (A2s) 3800
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 10
    • Power loss (W) 14
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC-UL
    • Weight (g) 800
  • Fuse NH3L gPV UL 2579 1100VDC 250A
    2003129.250.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 250
    • Pre-arcing I2t value (A2s) 26500
    • Total I2t value (A2s) 130000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 48
    • Format Knife contacts
    • Dimension NH3L
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse NH1XL gPV 1100V DC 50A
    2002820.50.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 50
    • Pre-arcing I2t value (A2s) 480
    • Total I2t value (A2s) 2000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 10
    • Power loss (W) 12
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC-UL
    • Weight (g) 800
  • Fuse SQB2 screw fixing gPV UL 2579 1100VDC 400A
    2003428.400.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 400
    • Pre-arcing I2t value (A2s) 80000
    • Total I2t value (A2s) 390000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 77
    • Format Screw fixing
    • Dimension 2 US
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse SQB2 US style gPV UL 2579 1100VDC 315A
    2003429.315.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 315
    • Pre-arcing I2t value (A2s) 38000
    • Total I2t value (A2s) 185000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 59
    • Format Screw fixing
    • Dimension 2 US
    • Weight (g) 1380
  • Fuse NH1XL gPV UL 2579 1100V DC 160A
    2002829.160.0
    Manufacturer: SIBA

    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 7600
    • Total I2t value (A2s) 25000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 36
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC
    • Weight (g) 780
  • Fuse SQB2 screw fixing gPV UL 2579 1100VDC 200A
    2003428.200.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 13000
    • Total I2t value (A2s) 63000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 39
    • Format Screw fixing
    • Dimension 2 US
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse NH3L gPV UL 2579 1100VDC 200A
    2003129.200.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 200
    • Pre-arcing I2t value (A2s) 13000
    • Total I2t value (A2s) 63000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 42
    • Format Knife contacts
    • Dimension NH3L
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse NH1XL gPV 1100V DC 160A
    2002820.160.0
    Manufacturer: SIBA

    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 160
    • Pre-arcing I2t value (A2s) 11200
    • Total I2t value (A2s) 47000
    • Voltage of total I2t test 1200
    • Rated break.capacity I1 DC (A) 30000
    • Time costant L/R (ms) 10
    • Power loss (W) 30
    • Format Knife contacts
    • Dimension NH1XL
    • Homologations IEC-UL
    • Weight (g) 770
  • Fuse NH3L gPV 1100VDC 315A
    2023129.315.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 315
    • Pre-arcing I2t value (A2s) 57000
    • Total I2t value (A2s) 257000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 50000
    • Power loss (W) 55
    • Homologations IEC-UL
  • Fuse SQB3 1100VDC gPV knife 167mm 315A
    2023529.315.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 315
    • Pre-arcing I2t value (A2s) 57000
    • Total I2t value (A2s) 257000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 50000
    • Power loss (W) 55
    • Homologations IEC-UL
  • Fuse SQB2 screw fixing gPV UL 2579 1100VDC 300A
    2003428.300.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 300
    • Pre-arcing I2t value (A2s) 38000
    • Total I2t value (A2s) 185000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 56
    • Format Screw fixing
    • Dimension 2 US
    • Homologations IEC-UL
    • Weight (g) 1380
  • Fuse SQB3 1100VDC gPV US standard 400A
    2023428.400.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 400
    • Pre-arcing I2t value (A2s) 106000
    • Total I2t value (A2s) 476000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 50000
    • Power loss (W) 64
    • Homologations IEC-UL
  • Fuse NH3L gPV 1100VDC 350A
    2023129.350.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 350
    • Pre-arcing I2t value (A2s) 80000
    • Total I2t value (A2s) 360000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 50000
    • Power loss (W) 57
    • Homologations IEC-UL
  • Fuse SQB2 US style gPV UL 2579 1100VDC 250A
    2003429.250.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 250
    • Pre-arcing I2t value (A2s) 26500
    • Total I2t value (A2s) 130000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 42
    • Format Screw fixing
    • Dimension 2 US
    • Weight (g) 1380
  • Fuse SQB1 screw M8 gPV 1100VDC with switch adapter 80A
    2001927.80.0
    Manufacturer: SIBA

     
    • Class gPV
    • Rated Voltage Un DC (V) 1100
    • Rated current In (A) 80
    • Pre-arcing I2t value (A2s) 1100
    • Total I2t value (A2s) 4000
    • Voltage of total I2t test 1100
    • Rated break.capacity I1 DC (A) 30000
    • Power loss (W) 23
    • Format Screw fixing
    • Dimension 1 screw M8
    • Homologations IEC
Accept

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies. More information